TY - JOUR
T1 - A highly sensitive multiplex immunoassay for inflammatory cytokines in dried blood spots
AU - McDade, Thomas W.
AU - Miller, Aaron
AU - Tran, Tina T.
AU - Borders, Ann E.B.
AU - Miller, Greg
N1 - Publisher Copyright:
© 2020 Wiley Periodicals LLC.
PY - 2021/11/1
Y1 - 2021/11/1
N2 - Objectives: Inflammatory cytokines are key regulators of inflammation, but current measurement approaches require venous blood to quantify low circulating concentrations associated with chronic, low-grade inflammation. This article describes a highly sensitive multiplex immunoassay protocol for the measurement of IL6, IL8, IL10, and TNFα in finger stick dried blood spot (DBS) samples. Methods: The protocol uses a multiplex electrochemiluminescent immunoassay platform. The following measures of assay performance were evaluated: reliability (inter-assay percent coefficient of variation; %CV), precision (intra-assay %CV), lower limit of detection (LLD), linearity of dilution, and agreement with results from matched plasma samples. Results: Analysis of three control samples across the assay range indicated an acceptable level of precision and reliability for each cytokine. Linearity of dilution returned average values that ranged from 104.1 to 127.6% of expected. Lower limits of detection for IL6, IL8, and IL10 were <0.5, and <1.0 pg/ml for TNFα. Level of agreement in results between matched DBS and plasma samples was high for all cytokines except for IL8. Conclusions: Finger stick DBS sampling provides a viable alternative to venipuncture for the quantification of IL6, IL10, and TNFα at low concentrations associated with chronic inflammation. The presence of red blood cells may interfere with the quantification of IL8 in DBS. In facilitating blood collection in nonclinical settings this method can advance scientific understandings of how social and ecological contexts shape immune function and health over the life course.
AB - Objectives: Inflammatory cytokines are key regulators of inflammation, but current measurement approaches require venous blood to quantify low circulating concentrations associated with chronic, low-grade inflammation. This article describes a highly sensitive multiplex immunoassay protocol for the measurement of IL6, IL8, IL10, and TNFα in finger stick dried blood spot (DBS) samples. Methods: The protocol uses a multiplex electrochemiluminescent immunoassay platform. The following measures of assay performance were evaluated: reliability (inter-assay percent coefficient of variation; %CV), precision (intra-assay %CV), lower limit of detection (LLD), linearity of dilution, and agreement with results from matched plasma samples. Results: Analysis of three control samples across the assay range indicated an acceptable level of precision and reliability for each cytokine. Linearity of dilution returned average values that ranged from 104.1 to 127.6% of expected. Lower limits of detection for IL6, IL8, and IL10 were <0.5, and <1.0 pg/ml for TNFα. Level of agreement in results between matched DBS and plasma samples was high for all cytokines except for IL8. Conclusions: Finger stick DBS sampling provides a viable alternative to venipuncture for the quantification of IL6, IL10, and TNFα at low concentrations associated with chronic inflammation. The presence of red blood cells may interfere with the quantification of IL8 in DBS. In facilitating blood collection in nonclinical settings this method can advance scientific understandings of how social and ecological contexts shape immune function and health over the life course.
UR - http://www.scopus.com/inward/record.url?scp=85098447819&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85098447819&partnerID=8YFLogxK
U2 - 10.1002/ajhb.23558
DO - 10.1002/ajhb.23558
M3 - Article
C2 - 33382166
AN - SCOPUS:85098447819
SN - 1042-0533
VL - 33
JO - American Journal of Human Biology
JF - American Journal of Human Biology
IS - 6
M1 - e23558
ER -