TY - JOUR
T1 - Accuracy of Radiographic Displacement Measurement in a Pelvic Ring Injury Model
AU - Hashmi, Sohaib Zafar
AU - Butler, Bennet
AU - Johnson, Daniel
AU - Wun, Kelly
AU - Sherman, Alan
AU - Summers, Hobie
AU - Stover, Michael
N1 - Publisher Copyright:
© American Academy of Orthopaedic Surgeons.
PY - 2022/1/15
Y1 - 2022/1/15
N2 - Background:Pelvic ring injury outcome studies rely on radiographic assessment. To date, no study investigates the accuracy of radiographic measurement. The aim of this study was to assess the accuracy and interobserver reliability of pelvic ring displacement measurement in an injury model. We hypothesize that current radiographic measurement methods do not accurately quantify the three-dimensional pelvic ring displacement.Methods:Ten orthopaedic traumatologists evaluated 12 pelvic ring injury model displacements using AP, inlet, and outlet radiographs and axial CT images. Observers completed a survey of demographic and treatment approach strategies. Radiographic displacement measurements in axial, coronal, and sagittal planes were analyzed for accuracy using. Absolute displacement measurements were categorized with Matta and Tornetta grading system for Fleiss Kappa inter-reliability correlation evaluation.Results:The mean age of orthopaedic traumatologists was 47.5 years (range 36 to 59) with a mean 15.3 years (range 4 to 27) of pelvic fracture surgery experience. Radiographic measurement of isolated uniplanar of pelvic displacement in axial, sagittal, or coronal plane alone was more accurate than multiplanar pelvic displacements with more than one plane of displacement, 6.6 ± 5.7 mm error compared with 9.6 ± 6.3 mm error, respectively (P = 0.0035). Measurement accuracy was greater with isolated coronal plane (4 ± 3.5 mm error) compared with isolated axial plane (9.9 ± 7.1 mm error) or isolated sagittal plane displacement (6.7 ± 4 mm error). Interrater reliability for the radiographic displacement measurement by observers showed an overall poor agreement with 0.24.Conclusion:Radiographic displacement measurement in these modeled pelvic ring injuries has notable inaccuracy among various measurement methods. Coronal and sagittal plane radiographic displacement measurements are more accurate compared with axial plane measurement. The reporting of radiographic displacement measurement outcomes in clinical research studies should be critically evaluated, and standardization of pelvic ring injury displacement may not be achievable with radiography.
AB - Background:Pelvic ring injury outcome studies rely on radiographic assessment. To date, no study investigates the accuracy of radiographic measurement. The aim of this study was to assess the accuracy and interobserver reliability of pelvic ring displacement measurement in an injury model. We hypothesize that current radiographic measurement methods do not accurately quantify the three-dimensional pelvic ring displacement.Methods:Ten orthopaedic traumatologists evaluated 12 pelvic ring injury model displacements using AP, inlet, and outlet radiographs and axial CT images. Observers completed a survey of demographic and treatment approach strategies. Radiographic displacement measurements in axial, coronal, and sagittal planes were analyzed for accuracy using. Absolute displacement measurements were categorized with Matta and Tornetta grading system for Fleiss Kappa inter-reliability correlation evaluation.Results:The mean age of orthopaedic traumatologists was 47.5 years (range 36 to 59) with a mean 15.3 years (range 4 to 27) of pelvic fracture surgery experience. Radiographic measurement of isolated uniplanar of pelvic displacement in axial, sagittal, or coronal plane alone was more accurate than multiplanar pelvic displacements with more than one plane of displacement, 6.6 ± 5.7 mm error compared with 9.6 ± 6.3 mm error, respectively (P = 0.0035). Measurement accuracy was greater with isolated coronal plane (4 ± 3.5 mm error) compared with isolated axial plane (9.9 ± 7.1 mm error) or isolated sagittal plane displacement (6.7 ± 4 mm error). Interrater reliability for the radiographic displacement measurement by observers showed an overall poor agreement with 0.24.Conclusion:Radiographic displacement measurement in these modeled pelvic ring injuries has notable inaccuracy among various measurement methods. Coronal and sagittal plane radiographic displacement measurements are more accurate compared with axial plane measurement. The reporting of radiographic displacement measurement outcomes in clinical research studies should be critically evaluated, and standardization of pelvic ring injury displacement may not be achievable with radiography.
UR - http://www.scopus.com/inward/record.url?scp=85123036606&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85123036606&partnerID=8YFLogxK
U2 - 10.5435/JAAOS-D-20-01055
DO - 10.5435/JAAOS-D-20-01055
M3 - Article
C2 - 34520445
AN - SCOPUS:85123036606
SN - 1067-151X
VL - 30
SP - E173-E181
JO - The Journal of the American Academy of Orthopaedic Surgeons
JF - The Journal of the American Academy of Orthopaedic Surgeons
IS - 2
ER -