T1 - An electrode array for limiting blood loss during liver resection
T2 - Optimization via mathematical modeling
AU - Strigel, R. M.
AU - Schutt, D. J.
AU - Webster, J. G.
AU - Mahvi, D. M.
AU - Haemmerich, D.
PY - 2010
Y1 - 2010
N2 - Liver resection is the current standard treatment for patients with both primary and metastatic liver cancer. The principal causes of morbidity and mortality after liver resection are related to blood loss (typically between 0.5 and 1 L), especially in cases where transfusion is required. Blood transfusions have been correlated with decreased long-term survival, increased risk of perioperative mortality and complications. The goal of this study was to evaluate different designs of a radiofrequency (RF) electrode array for use during liver resection. The purpose of this electrode array is to coagulate a slice of tissue including large vessels before resecting along that plane, thereby significantly reducing blood loss. Finite Element Method models were created to evaluate monopolar and bipolar power application, needle and blade shaped electrodes, as well as different electrode distances. Electric current density, temperature distribution, and coagulation zone sizes were measured. The best performance was achieved with a design of blade shaped electrodes (5×0.1 mm cross section) spaced 1.5 cm apart. The electrodes have power applied in bipolar mode to two adjacent electrodes, then switched sequentially in short intervals between electrode pairs to rapidly heat the tissue slice. This device produces a ~1.5 cm wide coagulation zone, with temperatures over 97°C throughout the tissue slice within 3 min, and may facilitate coagulation of large vessels.
AB - Liver resection is the current standard treatment for patients with both primary and metastatic liver cancer. The principal causes of morbidity and mortality after liver resection are related to blood loss (typically between 0.5 and 1 L), especially in cases where transfusion is required. Blood transfusions have been correlated with decreased long-term survival, increased risk of perioperative mortality and complications. The goal of this study was to evaluate different designs of a radiofrequency (RF) electrode array for use during liver resection. The purpose of this electrode array is to coagulate a slice of tissue including large vessels before resecting along that plane, thereby significantly reducing blood loss. Finite Element Method models were created to evaluate monopolar and bipolar power application, needle and blade shaped electrodes, as well as different electrode distances. Electric current density, temperature distribution, and coagulation zone sizes were measured. The best performance was achieved with a design of blade shaped electrodes (5×0.1 mm cross section) spaced 1.5 cm apart. The electrodes have power applied in bipolar mode to two adjacent electrodes, then switched sequentially in short intervals between electrode pairs to rapidly heat the tissue slice. This device produces a ~1.5 cm wide coagulation zone, with temperatures over 97°C throughout the tissue slice within 3 min, and may facilitate coagulation of large vessels.
UR - http://www.scopus.com/inward/record.url?scp=78249268271&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=78249268271&partnerID=8YFLogxK
U2 - 10.2174/1874120701004020039
DO - 10.2174/1874120701004020039
M3 - Article
C2 - 20309395
AN - SCOPUS:78249268271
SN - 1874-1207
VL - 4
SP - 39
EP - 46
JO - Open Biomedical Engineering Journal
JF - Open Biomedical Engineering Journal
IS - SPEC. ISSUE 1
ER -