Aortic Volumetry at Contrast-Enhanced Magnetic Resonance Angiography: Feasibility as a Sensitive Method for Monitoring Bicuspid Aortic Valve Aortopathy

Brian Trinh, Iram Dubin, Ozair Rahman, Marcos P. Ferreira Botelho, Nicholas Naro, James C. Carr, Jeremy D. Collins, Alex J. Barker*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

20 Scopus citations

Abstract

Objectives Bicuspid aortic valve patients can develop thoracic aortic aneurysms and therefore require serial imaging to monitor aortic growth. This study investigates the reliability of contrast-enhanced magnetic resonance angiography (CEMRA) volumetry compared with 2-dimensional diameter measurements to identify thoracic aortic aneurysm growth. Materials and Methods A retrospective, institutional review board-approved, and Health Insurance Portability and Accountability Act-compliant study was conducted on 20 bicuspid aortic valve patients (45 ± 8.9 years, 20% women) who underwent serial CEMRA with a minimum imaging follow-up of 11 months. Magnetic resonance imaging was performed at 1.5 T with electrocardiogram-gated, time-resolved CEMRA. Independent observers measured the diameter at the sinuses of Valsalva (SOVs) and mid ascending aorta (MAA) as well as ascending aorta volume between the aortic valve annulus and innominate branch. Intraobserver/interobserver coefficient of variation (COV) and intraclass correlation coefficient (ICC) were computed to assess reliability. Growth rates were calculated and assessed by Student t test (P < 0.05, significant). The diameter of maximal growth (DMG), defined as the diameter at SOV or MAA with the faster growth rate, was recorded. Results The mean time of follow-up was 2.6 ± 0.82 years. The intraobserver COV was 0.01 for SOV, 0.02 for MAA, and 0.02 for volume (interobserver COV: 0.02, 0.03, 0.04, respectively). The ICC was 0.83 for SOV, 0.86 for MAA, 0.90 for DMG, and 0.95 for volume. Average aortic measurements at baseline and (follow-up) were 42 ± 3 mm (42 ± 3 mm, P = 0.11) at SOV, 46 ± 4 mm (47 ± 4 mm, P < 0.05) at MAA, and 130 ± 23 mL (144 ± 24 mL, P < 0.05). Average size changes were 0.2 ± 0.6 mm/y (1% ± 2%) at SOV, 0.5 ± 0.8 mm/y (1% ± 2%) at MAA, 0.7 ± 0.7 mm/y (2% ± 2%) at DMG, and 6 ± 3 mL/y (4% ± 3%) with volumetry. Conclusions Three-dimensional CEMRA volumetry exhibited a larger effect when examining percentage growth, a better ICC, and a marginally lower COV. Volumetry may be more sensitive to growth and possibly less affected by error than diameter measurements.

Original languageEnglish (US)
Pages (from-to)216-222
Number of pages7
JournalInvestigative radiology
Volume52
Issue number4
DOIs
StatePublished - Apr 1 2017

Funding

Keywords

  • ascending aorta aneurysm
  • bicuspid aortic valve
  • contrast-enhanced magnetic resonance angiography volumetry
  • thoracic ascending aorta

ASJC Scopus subject areas

  • General Medicine

Fingerprint

Dive into the research topics of 'Aortic Volumetry at Contrast-Enhanced Magnetic Resonance Angiography: Feasibility as a Sensitive Method for Monitoring Bicuspid Aortic Valve Aortopathy'. Together they form a unique fingerprint.

Cite this