TY - JOUR
T1 - Aortic Volumetry at Contrast-Enhanced Magnetic Resonance Angiography
T2 - Feasibility as a Sensitive Method for Monitoring Bicuspid Aortic Valve Aortopathy
AU - Trinh, Brian
AU - Dubin, Iram
AU - Rahman, Ozair
AU - Ferreira Botelho, Marcos P.
AU - Naro, Nicholas
AU - Carr, James C.
AU - Collins, Jeremy D.
AU - Barker, Alex J.
N1 - Publisher Copyright:
© 2017 Wolters Kluwer Health, Inc. All rights reserved.
PY - 2017/4/1
Y1 - 2017/4/1
N2 - Objectives Bicuspid aortic valve patients can develop thoracic aortic aneurysms and therefore require serial imaging to monitor aortic growth. This study investigates the reliability of contrast-enhanced magnetic resonance angiography (CEMRA) volumetry compared with 2-dimensional diameter measurements to identify thoracic aortic aneurysm growth. Materials and Methods A retrospective, institutional review board-approved, and Health Insurance Portability and Accountability Act-compliant study was conducted on 20 bicuspid aortic valve patients (45 ± 8.9 years, 20% women) who underwent serial CEMRA with a minimum imaging follow-up of 11 months. Magnetic resonance imaging was performed at 1.5 T with electrocardiogram-gated, time-resolved CEMRA. Independent observers measured the diameter at the sinuses of Valsalva (SOVs) and mid ascending aorta (MAA) as well as ascending aorta volume between the aortic valve annulus and innominate branch. Intraobserver/interobserver coefficient of variation (COV) and intraclass correlation coefficient (ICC) were computed to assess reliability. Growth rates were calculated and assessed by Student t test (P < 0.05, significant). The diameter of maximal growth (DMG), defined as the diameter at SOV or MAA with the faster growth rate, was recorded. Results The mean time of follow-up was 2.6 ± 0.82 years. The intraobserver COV was 0.01 for SOV, 0.02 for MAA, and 0.02 for volume (interobserver COV: 0.02, 0.03, 0.04, respectively). The ICC was 0.83 for SOV, 0.86 for MAA, 0.90 for DMG, and 0.95 for volume. Average aortic measurements at baseline and (follow-up) were 42 ± 3 mm (42 ± 3 mm, P = 0.11) at SOV, 46 ± 4 mm (47 ± 4 mm, P < 0.05) at MAA, and 130 ± 23 mL (144 ± 24 mL, P < 0.05). Average size changes were 0.2 ± 0.6 mm/y (1% ± 2%) at SOV, 0.5 ± 0.8 mm/y (1% ± 2%) at MAA, 0.7 ± 0.7 mm/y (2% ± 2%) at DMG, and 6 ± 3 mL/y (4% ± 3%) with volumetry. Conclusions Three-dimensional CEMRA volumetry exhibited a larger effect when examining percentage growth, a better ICC, and a marginally lower COV. Volumetry may be more sensitive to growth and possibly less affected by error than diameter measurements.
AB - Objectives Bicuspid aortic valve patients can develop thoracic aortic aneurysms and therefore require serial imaging to monitor aortic growth. This study investigates the reliability of contrast-enhanced magnetic resonance angiography (CEMRA) volumetry compared with 2-dimensional diameter measurements to identify thoracic aortic aneurysm growth. Materials and Methods A retrospective, institutional review board-approved, and Health Insurance Portability and Accountability Act-compliant study was conducted on 20 bicuspid aortic valve patients (45 ± 8.9 years, 20% women) who underwent serial CEMRA with a minimum imaging follow-up of 11 months. Magnetic resonance imaging was performed at 1.5 T with electrocardiogram-gated, time-resolved CEMRA. Independent observers measured the diameter at the sinuses of Valsalva (SOVs) and mid ascending aorta (MAA) as well as ascending aorta volume between the aortic valve annulus and innominate branch. Intraobserver/interobserver coefficient of variation (COV) and intraclass correlation coefficient (ICC) were computed to assess reliability. Growth rates were calculated and assessed by Student t test (P < 0.05, significant). The diameter of maximal growth (DMG), defined as the diameter at SOV or MAA with the faster growth rate, was recorded. Results The mean time of follow-up was 2.6 ± 0.82 years. The intraobserver COV was 0.01 for SOV, 0.02 for MAA, and 0.02 for volume (interobserver COV: 0.02, 0.03, 0.04, respectively). The ICC was 0.83 for SOV, 0.86 for MAA, 0.90 for DMG, and 0.95 for volume. Average aortic measurements at baseline and (follow-up) were 42 ± 3 mm (42 ± 3 mm, P = 0.11) at SOV, 46 ± 4 mm (47 ± 4 mm, P < 0.05) at MAA, and 130 ± 23 mL (144 ± 24 mL, P < 0.05). Average size changes were 0.2 ± 0.6 mm/y (1% ± 2%) at SOV, 0.5 ± 0.8 mm/y (1% ± 2%) at MAA, 0.7 ± 0.7 mm/y (2% ± 2%) at DMG, and 6 ± 3 mL/y (4% ± 3%) with volumetry. Conclusions Three-dimensional CEMRA volumetry exhibited a larger effect when examining percentage growth, a better ICC, and a marginally lower COV. Volumetry may be more sensitive to growth and possibly less affected by error than diameter measurements.
KW - ascending aorta aneurysm
KW - bicuspid aortic valve
KW - contrast-enhanced magnetic resonance angiography volumetry
KW - thoracic ascending aorta
UR - http://www.scopus.com/inward/record.url?scp=84995768092&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84995768092&partnerID=8YFLogxK
U2 - 10.1097/RLI.0000000000000332
DO - 10.1097/RLI.0000000000000332
M3 - Article
C2 - 27861233
AN - SCOPUS:84995768092
SN - 0020-9996
VL - 52
SP - 216
EP - 222
JO - Investigative radiology
JF - Investigative radiology
IS - 4
ER -