Bicuspid aortic cusp fusion morphology alters aortic three-dimensional outflow patterns, wall shear stress, and expression of aortopathy

Riti Mahadevia, Alex J. Barker, Susanne Schnell, Pegah Entezari, Preeti Kansal, Paul W.M. Fedak, S. Chris Malaisrie, Patrick McCarthy, Jeremy Collins, James Carr, Michael Markl*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

347 Scopus citations

Abstract

Background: Aortic 3-dimensional blood flow was analyzed to investigate altered ascending aorta (AAo) hemodynamics in bicuspid aortic valve (BAV) patients and its association with differences in cusp fusion patterns (right-left, RL versus right-noncoronary, RN) and expression of aortopathy. Methods and Results: Four-dimensional flow MRI measured in vivo 3-dimensional blood flow in the aorta of 75 susbjects: BAV patients with aortic dilatation stratified by leaflet fusion pattern (n=15 RL-BAV, mid AAo diameter=39. 9±4.4 mm; n=15 RN-BAV, 39.6±7.2 mm); aorta size controls with tricuspid aortic valves (n=30, 41.0±4.4 mm); healthy volunteers (n=15, 24.9±3.0 mm). Aortopathy type (0-3), systolic flow angle, flow displacement, and regional wall shear stress were determined for all subjects. Eccentric outflow jet patterns in BAV patients resulted in elevated regional wall shear stress (P<0.0125) at the right-anterior walls for RL-BAV and right-posterior walls for RN-BAV in comparison with aorta size controls. Dilatation of the aortic root only (type 1) or involving the entire AAo and arch (type 3) was found in the majority of RN-BAV patients (87%) but was mostly absent for RL-BAV patients (87% type 2). Differences in aortopathy type between RL-BAV and RN-BAV patients were associated with altered flow displacement in the proximal and mid AAo for type 1 (42%-81% decrease versus type 2) and distal AAo for type 3 (33%-39% increase versus type 2). Conclusions-The presence and type of BAV fusion was associated with changes in regional wall shear stress distribution, systolic flow eccentricity, and expression of BAV aortopathy. Hemodynamic markers suggest a physiological mechanism by which the valve morphology phenotype can influence phenotypes of BAV aortopathy.

Original languageEnglish (US)
Pages (from-to)673-682
Number of pages10
JournalCirculation
Volume129
Issue number6
DOIs
StatePublished - Feb 11 2014

Keywords

  • Aortic diseases
  • Bicuspid aortic valve
  • Hemodynamics
  • Magnetic resonance imaging

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Physiology (medical)

Fingerprint

Dive into the research topics of 'Bicuspid aortic cusp fusion morphology alters aortic three-dimensional outflow patterns, wall shear stress, and expression of aortopathy'. Together they form a unique fingerprint.

Cite this