TY - JOUR
T1 - Breast cancer screening in women with cerebral palsy
T2 - Could care delivery be improved?
AU - Nandam, Neeharika
AU - Gaebler-Spira, Deborah
AU - Byrne, Rachel
AU - Wolfman, Judith
AU - Reis, Judy Panko
AU - Hung, Chun Wai
AU - Todd, Allison
AU - Durkin, Jordyn
AU - Marciniak, Christina
N1 - Funding Information:
Research supported by the Cerebral Palsy Foundation from a donation from 100 Women in Finance.
Publisher Copyright:
© 2018 Elsevier Inc.
PY - 2018/7
Y1 - 2018/7
N2 - Background: Women with disabilities (WWD) have reported lower mammography rates than the general population, however rates for women with cerebral palsy (CP) have not been specifically studied. Objective: To evaluate mammography rates in women with CP and to identify strengths and barriers with their screening experience. Methods: Women with CP 40 years or older (n = 118) participating in a prospective cross-sectional survey were queried regarding screening status, imaging modality, and accommodation needs and availability. Categorical variables were summarized and Chi-square testing used to assess factors contributing to screening compliance. The effect of functional factors on screening was evaluated using logistic regression. Results: 77 women (65.3%) had mammograms within the past two years; 56 (47.5%) were screening mammograms. Severity of fine motor deficits was associated with lack of screening (OR 0.559, p = 0.019). 85 (72.0%) experienced positive staff attitudes. Facilities most often met needs for ramps, elevators, and/or wide doorways (92.9%), exam explanations (84.4%), and accessible parking (82.5%). Needs least often met included accommodations for standing (59.3%) or for difficulties with arm/shoulder positioning (57.1%), and wheelchair-accessible mammogram machines (59.1%). Conclusions: The screening compliance rate for women with CP is low, although the 2-year mammography rate is comparable to that reported for WWD and the general female U.S. population. Women were usually offered respectful care. Adequate physical accommodations during the procedure were reported less often than overall facility environmental accommodations. These findings demonstrate the need for improved screening rates in women with CP, and highlight areas for improving their screening experience.
AB - Background: Women with disabilities (WWD) have reported lower mammography rates than the general population, however rates for women with cerebral palsy (CP) have not been specifically studied. Objective: To evaluate mammography rates in women with CP and to identify strengths and barriers with their screening experience. Methods: Women with CP 40 years or older (n = 118) participating in a prospective cross-sectional survey were queried regarding screening status, imaging modality, and accommodation needs and availability. Categorical variables were summarized and Chi-square testing used to assess factors contributing to screening compliance. The effect of functional factors on screening was evaluated using logistic regression. Results: 77 women (65.3%) had mammograms within the past two years; 56 (47.5%) were screening mammograms. Severity of fine motor deficits was associated with lack of screening (OR 0.559, p = 0.019). 85 (72.0%) experienced positive staff attitudes. Facilities most often met needs for ramps, elevators, and/or wide doorways (92.9%), exam explanations (84.4%), and accessible parking (82.5%). Needs least often met included accommodations for standing (59.3%) or for difficulties with arm/shoulder positioning (57.1%), and wheelchair-accessible mammogram machines (59.1%). Conclusions: The screening compliance rate for women with CP is low, although the 2-year mammography rate is comparable to that reported for WWD and the general female U.S. population. Women were usually offered respectful care. Adequate physical accommodations during the procedure were reported less often than overall facility environmental accommodations. These findings demonstrate the need for improved screening rates in women with CP, and highlight areas for improving their screening experience.
KW - Breast cancer
KW - Breast ultrasound
KW - Cerebral palsy
KW - Mammography
KW - Screening
UR - http://www.scopus.com/inward/record.url?scp=85042646325&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85042646325&partnerID=8YFLogxK
U2 - 10.1016/j.dhjo.2018.02.002
DO - 10.1016/j.dhjo.2018.02.002
M3 - Article
C2 - 29500093
AN - SCOPUS:85042646325
SN - 1936-6574
VL - 11
SP - 435
EP - 441
JO - Disability and Health Journal
JF - Disability and Health Journal
IS - 3
ER -