Abstract

Technical measurements of the Sony Multiscan 17se were made and are reported in the belief that they would be useful to visual scientists who consider employing this device as a display unit. Luminance, spatial uniformity, luminance additivity between the output of the guns, CIE1931 chromaticity coordinates, and gamma correction parameters were measured. The characteristics of individual monitors will probably be different from the one studied here but it is believed that the results obtained serve as a fair indication of what might be expected from this device.

Original languageEnglish (US)
Pages (from-to)345-351
Number of pages7
JournalSpatial Vision
Volume10
Issue number4
DOIs
StatePublished - 1997

Funding

Supported by NIH R01EY06669. We wish to thank Dr Ch. Enroth-Cugell and Tom Robson for comments on the text and Dr Steven K. Shevell for loaning the Minolta and the International

ASJC Scopus subject areas

  • Experimental and Cognitive Psychology
  • Computer Vision and Pattern Recognition

Fingerprint

Dive into the research topics of 'Characteristics of the Sony Multiscan 17se Trinitron color graphic display'. Together they form a unique fingerprint.