TY - JOUR
T1 - Clinical and radiographic comparisons of two different radial head implant designs
AU - Berschback, John C.
AU - Lynch, T. Sean
AU - Kalainov, David M.
AU - Wysocki, Robert W.
AU - Merk, Bradley R.
AU - Cohen, Mark S.
PY - 2013/8
Y1 - 2013/8
N2 - Background: There is little comparative data to guide implant choice for radial head replacements. The purpose of this study was to evaluate the clinical and radiographic results between patients who received a smooth-stemmed bipolar radial head implant and patients who received an in-growth monopolar prosthesis. Methods: Twenty-seven patients requiring a metallic radial head implant in the management of acute or chronic elbow trauma were evaluated. Fourteen patients received a smooth-stemmed bipolar prosthesis and 13 patients received a press-fit monopolar prosthesis. Patients returned for follow-up at an average of 33 months (range, 18-57). Outcome assessments included joint motion, elbow stability, grip strength, pain, the Mayo Elbow Performance Index, and the Disability of Arm, Shoulder and Hand questionnaire. Radiographs were reviewed for joint congruence, ectopic bone, periprosthetic osteolysis, degenerative arthritis, and capitellar wear, and selected patients were tested for inflammatory markers and metal ion levels. Results: The differences between patient groups for elbow flexion and forearm pronation averaged 10° or less. There were no other pertinent differences between groups for standardized patient and examiner-determined outcomes. There was a trend for ectopic bone to develop more commonly around the smooth-stemmed implants, while periprosthetic osteolysis was more pronounced in cases with the press-fit design. Inflammatory markers were normal, and metal ion levels did not exceed values reported for a well-functioning hip arthroplasty. Conclusion: Outcomes at short- to mid-term follow-up were similar with either implant design. Loosening of a press-fit prosthesis may lead to extensive osteolysis, but of undetermined clinical consequence.
AB - Background: There is little comparative data to guide implant choice for radial head replacements. The purpose of this study was to evaluate the clinical and radiographic results between patients who received a smooth-stemmed bipolar radial head implant and patients who received an in-growth monopolar prosthesis. Methods: Twenty-seven patients requiring a metallic radial head implant in the management of acute or chronic elbow trauma were evaluated. Fourteen patients received a smooth-stemmed bipolar prosthesis and 13 patients received a press-fit monopolar prosthesis. Patients returned for follow-up at an average of 33 months (range, 18-57). Outcome assessments included joint motion, elbow stability, grip strength, pain, the Mayo Elbow Performance Index, and the Disability of Arm, Shoulder and Hand questionnaire. Radiographs were reviewed for joint congruence, ectopic bone, periprosthetic osteolysis, degenerative arthritis, and capitellar wear, and selected patients were tested for inflammatory markers and metal ion levels. Results: The differences between patient groups for elbow flexion and forearm pronation averaged 10° or less. There were no other pertinent differences between groups for standardized patient and examiner-determined outcomes. There was a trend for ectopic bone to develop more commonly around the smooth-stemmed implants, while periprosthetic osteolysis was more pronounced in cases with the press-fit design. Inflammatory markers were normal, and metal ion levels did not exceed values reported for a well-functioning hip arthroplasty. Conclusion: Outcomes at short- to mid-term follow-up were similar with either implant design. Loosening of a press-fit prosthesis may lead to extensive osteolysis, but of undetermined clinical consequence.
KW - Elbow joint
KW - Heterotopic ossification
KW - Level III
KW - Metal ions
KW - Osteolysis
KW - Radial head arthroplasty
KW - Radial head fracture
KW - Retrospective Cohort Study
KW - Treatment Study
UR - http://www.scopus.com/inward/record.url?scp=84880515024&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84880515024&partnerID=8YFLogxK
U2 - 10.1016/j.jse.2013.02.011
DO - 10.1016/j.jse.2013.02.011
M3 - Article
C2 - 23659806
AN - SCOPUS:84880515024
SN - 1058-2746
VL - 22
SP - 1108
EP - 1120
JO - Journal of Shoulder and Elbow Surgery
JF - Journal of Shoulder and Elbow Surgery
IS - 8
ER -