TY - JOUR
T1 - Correlation of transthoracic echocardiography-derived pulmonary to systemic flow ratio with hemodynamically estimated left to right shunt in atrial septal defects
AU - Faherty, Erin
AU - Rajagopal, Hari
AU - Lee, Simon
AU - Love, Barry
AU - Srivastava, Shubhika
AU - Parness, Ira
AU - Uppu, Santosh
N1 - Publisher Copyright:
© 2022 Wolters Kluwer Medknow Publications. All rights reserved.
PY - 2022/1/1
Y1 - 2022/1/1
N2 - Background: Transthoracic echocardiographic (TTE) estimation of the pulmonary to systemic flow ratio (Qp/Qs) is routinely used in clinical practice and is included in the American Society of Echocardiography Guidelines. We sought to assess its real-world applicability with a particular focus on hemodynamically significant shunt lesions. Methods: Retrospective single institutional review of TTE's in patients with secundum atrial septal defect prior to cardiac catheterization (cath) from 2012 to 2018 was performed (n = 109), those with technically limited images for Qp/Qs calculation (n = 11) and those with time interval between TTE and cath >60 days were excluded (n = 14). Qp/Qs was calculated from stored clips by previously described methods and correlated with those obtained by oximetry. Patients were subdivided into two age groups <21 (Group 1) and ≥22 years (Group 2). TTE and cath methods for Qp/Qs estimation were compared using paired t-test, Pearson's correlation coefficient, and Bland-Altman plots. Results: Eighty-four subjects met inclusion criteria (age range 3-78 years). Group 1 n = 35; median age 10 years; Group 2 n = 49; median age 49 years. Transthoracic echocardiogram was performed 19.5 ± 15 days prior to cath. Mean Qp/Qs derived by cath and TTE were 2.09 ± 0.9 versus 2.54 ± 1.2 (P < 0.0001). Overall correlation was poor between the methods (r 2 = 0.32, P < 0.0001) and continued to be poor for Groups 1 and 2 (r 2 = 0.24, P = 0.003 and r 2 = 0.40, P < 0.0001 respectively). Bland-Altman plots demonstrated poor agreement between the predetermined limits of agreement (-0.5-1.5). Conclusion: Transthoracic echocardiography estimated Qp/Qs, although routinely utilized in clinical practice, has poor correlation and agreement with oximetry-derived Qp/Qs. The test performs poorly in all age groups in detecting a hemodynamically significant shunt and tends to overestimate the degree of left to right shunt.
AB - Background: Transthoracic echocardiographic (TTE) estimation of the pulmonary to systemic flow ratio (Qp/Qs) is routinely used in clinical practice and is included in the American Society of Echocardiography Guidelines. We sought to assess its real-world applicability with a particular focus on hemodynamically significant shunt lesions. Methods: Retrospective single institutional review of TTE's in patients with secundum atrial septal defect prior to cardiac catheterization (cath) from 2012 to 2018 was performed (n = 109), those with technically limited images for Qp/Qs calculation (n = 11) and those with time interval between TTE and cath >60 days were excluded (n = 14). Qp/Qs was calculated from stored clips by previously described methods and correlated with those obtained by oximetry. Patients were subdivided into two age groups <21 (Group 1) and ≥22 years (Group 2). TTE and cath methods for Qp/Qs estimation were compared using paired t-test, Pearson's correlation coefficient, and Bland-Altman plots. Results: Eighty-four subjects met inclusion criteria (age range 3-78 years). Group 1 n = 35; median age 10 years; Group 2 n = 49; median age 49 years. Transthoracic echocardiogram was performed 19.5 ± 15 days prior to cath. Mean Qp/Qs derived by cath and TTE were 2.09 ± 0.9 versus 2.54 ± 1.2 (P < 0.0001). Overall correlation was poor between the methods (r 2 = 0.32, P < 0.0001) and continued to be poor for Groups 1 and 2 (r 2 = 0.24, P = 0.003 and r 2 = 0.40, P < 0.0001 respectively). Bland-Altman plots demonstrated poor agreement between the predetermined limits of agreement (-0.5-1.5). Conclusion: Transthoracic echocardiography estimated Qp/Qs, although routinely utilized in clinical practice, has poor correlation and agreement with oximetry-derived Qp/Qs. The test performs poorly in all age groups in detecting a hemodynamically significant shunt and tends to overestimate the degree of left to right shunt.
KW - Atrial septal defect
KW - left to right shunt
KW - oximetry
KW - transthoracic echocardiography
UR - http://www.scopus.com/inward/record.url?scp=85133262284&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85133262284&partnerID=8YFLogxK
U2 - 10.4103/apc.apc_139_21
DO - 10.4103/apc.apc_139_21
M3 - Article
C2 - 35847407
AN - SCOPUS:85133262284
SN - 0974-2069
VL - 15
SP - 20
EP - 26
JO - Annals of Pediatric Cardiology
JF - Annals of Pediatric Cardiology
IS - 1
ER -