TY - JOUR
T1 - Descriptors of Failed Extubation in Norwood Patients Using Physiologic Data Streaming
AU - Savorgnan, Fabio
AU - Loomba, Rohit S.
AU - Flores, Saul
AU - Rusin, Craig G.
AU - Zheng, Feng
AU - Hassan, Adel M.
AU - Acosta, Sebastian
N1 - Publisher Copyright:
© 2022, The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.
PY - 2023/2
Y1 - 2023/2
N2 - The objective of this study is to evaluate the utility of high-frequency physiologic data during the extubation process and other clinical variables for describing the physiologic profile of extubation failure in neonates with hypoplastic left heart syndrome (HLHS) post-Norwood procedure. This is a single-center, retrospective analysis. Extubation events were collected from January 2016 until July 2021. Extubation failure was defined as the need for re-intubation within 48 h of extubation. The data included streaming heart rate, respiratory rate, blood pressure, arterial oxygen saturation, and cerebral/renal near-infrared spectroscopy (NIRS). The most recent blood laboratory results before extubation were also included. These markers, demographics, clinical characteristics, and ventilatory settings were compared between successful and failed extubations. The analysis included 311 extubations. The extubation failure rate was 10%. According to univariable analyses, failed extubations were preceded by higher respiratory rates (p = 0.029), lower end-tidal CO2 (p = 0.009), lower pH (p = 0.043), lower serum bicarbonate (p = 0.030), and lower partial pressure of O2 (p = 0.022). In the first 10 min after extubation, the failed events were characterized by lower arterial (p = 0.028) and cerebral NIRS (p = 0.018) saturations. Failed events were associated with persistently lower values for cerebral NIRS 2 h post-extubation (p = 0.027). In multivariable analysis, vocal cord anomaly, cerebral NIRS at 10 min post-extubation, renal NIRS at pre-extubation and post-extubation, and end-tidal CO2 at pre-extubation remained as significant co-variables. Oximetric indices before, in the 10 min immediately after, and 2 h after extubation and vocal cords paralysis are associated with failed extubation events in patients with parallel circulation.
AB - The objective of this study is to evaluate the utility of high-frequency physiologic data during the extubation process and other clinical variables for describing the physiologic profile of extubation failure in neonates with hypoplastic left heart syndrome (HLHS) post-Norwood procedure. This is a single-center, retrospective analysis. Extubation events were collected from January 2016 until July 2021. Extubation failure was defined as the need for re-intubation within 48 h of extubation. The data included streaming heart rate, respiratory rate, blood pressure, arterial oxygen saturation, and cerebral/renal near-infrared spectroscopy (NIRS). The most recent blood laboratory results before extubation were also included. These markers, demographics, clinical characteristics, and ventilatory settings were compared between successful and failed extubations. The analysis included 311 extubations. The extubation failure rate was 10%. According to univariable analyses, failed extubations were preceded by higher respiratory rates (p = 0.029), lower end-tidal CO2 (p = 0.009), lower pH (p = 0.043), lower serum bicarbonate (p = 0.030), and lower partial pressure of O2 (p = 0.022). In the first 10 min after extubation, the failed events were characterized by lower arterial (p = 0.028) and cerebral NIRS (p = 0.018) saturations. Failed events were associated with persistently lower values for cerebral NIRS 2 h post-extubation (p = 0.027). In multivariable analysis, vocal cord anomaly, cerebral NIRS at 10 min post-extubation, renal NIRS at pre-extubation and post-extubation, and end-tidal CO2 at pre-extubation remained as significant co-variables. Oximetric indices before, in the 10 min immediately after, and 2 h after extubation and vocal cords paralysis are associated with failed extubation events in patients with parallel circulation.
KW - Extubation failure
KW - Near-infrared spectroscopy
KW - Norwood
KW - Oximetric monitoring
KW - Parallel circulation
KW - Single ventricle
UR - http://www.scopus.com/inward/record.url?scp=85144703027&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85144703027&partnerID=8YFLogxK
U2 - 10.1007/s00246-022-03084-8
DO - 10.1007/s00246-022-03084-8
M3 - Article
C2 - 36562780
AN - SCOPUS:85144703027
SN - 0172-0643
VL - 44
SP - 396
EP - 403
JO - Pediatric cardiology
JF - Pediatric cardiology
IS - 2
ER -