Differences in health-related quality of life by implant strategy: Analyses from the Interagency Registry for Mechanically Assisted Circulatory Support

Connie White-Williams*, Pariya L. Fazeli, James K. Kirklin, Salpy V. Pamboukian, Kathleen L. Grady

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

23 Scopus citations

Abstract

BACKGROUND: Midterm change in health-related quality of life (HRQOL) by left ventricular assist device (LVAD) implant strategy is unknown. The purpose of this study was to examine HRQOL by pre-operative implant strategy from before to 2 years after surgery. METHODS: Adult patients in the Interagency Registry for Mechanically Assisted Circulatory Support were stratified into 3 groups based on pre-implant device strategy: destination therapy (DT) (n = 2,901), bridge to transplant (BTT) (n = 2,209), and bridge to candidacy (BTC) (n = 3,076). HRQOL data were collected before and 2 years after surgery using the generic EQ-5D-3L survey and heart failure–specific Kansas City Cardiomyopathy Questionnaire (KCCQ-12). Statistical analyses included chi-square tests, analysis of variance, paired t-tests, and general linear random effects models. RESULTS: Between April 1, 2008 and June 30, 2013, 4,422 patients and 1,660 patients (majority males and ≥50 years) who received primary continuous flow LVADs completed baseline EQ-5D-3L and KCCQ-12 questionnaires, respectively, whereas 1,615 and 1,408 patients completed EQ-5D-3L and KCCQ-12 questionnaires at 2 years, respectively. Although paired t-tests and general linear random effects models showed that both heart failure–specific and generic HRQOL improved for all groups across time (p-values <0.05), some differences in HRQOL were found by implant strategy at baseline and 2 years, with a pattern favoring better functioning for patients with BTT. The BTT group reported significantly higher overall HRQOL pre-implant using the KCCQ-12 (BTT = 37.09, BTC = 33.57, and DT = 33.56) and at 2 years using the EQ-5D-3L (BTT = 75.18, BTC = 72.27, and DT = 70.87) (p-values <0.05), although these differences were not clinically important differences. Differences in HRQOL domains were also found. CONCLUSIONS: Using generic and heart failure–specific instruments, overall HRQOL generally improved from before to 2 years after mechanical circulatory support implant regardless of implant strategy, although important domain-specific differences by group were identified.

Original languageEnglish (US)
Pages (from-to)62-73
Number of pages12
JournalJournal of Heart and Lung Transplantation
Volume39
Issue number1
DOIs
StatePublished - Jan 2020

Funding

Drs White-Williams, Pamboukian, Grady, and Fazeli do not have any conflicts to disclose. This project was funded in part with Federal funds from the National Heart, Lung, and Blood Institute; National Institutes of Health; and Department of Health and Human Services, under Contract No. HHSN268201100025C. Dr. Kirklin has financial activities outside of the submitted work with personal fees for Society of Thoracic Surgeons and Xeltis.

Keywords

  • EQ-5D-3L
  • INTERMACS
  • KCCQ-12
  • implant strategy
  • mechanical circulatory support
  • quality of life

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Transplantation
  • Pulmonary and Respiratory Medicine
  • Surgery

Fingerprint

Dive into the research topics of 'Differences in health-related quality of life by implant strategy: Analyses from the Interagency Registry for Mechanically Assisted Circulatory Support'. Together they form a unique fingerprint.

Cite this