TY - JOUR
T1 - Doppler mitral pressure half-time
T2 - A clinical tool in search of theoretical justification
AU - Thomas, J. D.
AU - Weyman, A. E.
PY - 1987
Y1 - 1987
N2 - The Doppler determination of the mitral pressure half-time has gained widespread acceptance as a reliable estimate for mitral valve area, despite little theoretical basis for its “independence” of other hemodynamic variables. A simple model of the left atrium and mitral valve has been developed and a governing equation derived from fluid dynamics fundamentals. Solution of this equation indicates that the pressure half-time should vary inversely with mitral valve area, but also proportionally to net left atrial and ventricular compliance and to the square root of the peak transmitral gradient. This complex relation is apparently masked in the typical clinical situation because pressure and compliance tend to change in opposite directions, thereby partly offsetting each other. In several clinical settings, such as balloon mitral valvotomy, left ventricular hypertrophy and aortic regurgitation, changes in initial pressure and compliance may be large enough to alter the relation between mitral area and pressure half-time. This study reviews the development of the pressure half-time concept, presents an overall method for studying mitral valve flow using mathematical modeling and describes the effects of factors other than mitral valve area on pressure half-time.
AB - The Doppler determination of the mitral pressure half-time has gained widespread acceptance as a reliable estimate for mitral valve area, despite little theoretical basis for its “independence” of other hemodynamic variables. A simple model of the left atrium and mitral valve has been developed and a governing equation derived from fluid dynamics fundamentals. Solution of this equation indicates that the pressure half-time should vary inversely with mitral valve area, but also proportionally to net left atrial and ventricular compliance and to the square root of the peak transmitral gradient. This complex relation is apparently masked in the typical clinical situation because pressure and compliance tend to change in opposite directions, thereby partly offsetting each other. In several clinical settings, such as balloon mitral valvotomy, left ventricular hypertrophy and aortic regurgitation, changes in initial pressure and compliance may be large enough to alter the relation between mitral area and pressure half-time. This study reviews the development of the pressure half-time concept, presents an overall method for studying mitral valve flow using mathematical modeling and describes the effects of factors other than mitral valve area on pressure half-time.
UR - http://www.scopus.com/inward/record.url?scp=0023616591&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0023616591&partnerID=8YFLogxK
U2 - 10.1016/S0735-1097(87)80290-5
DO - 10.1016/S0735-1097(87)80290-5
M3 - Editorial
C2 - 3309007
AN - SCOPUS:0023616591
SN - 0735-1097
VL - 10
SP - 923
EP - 929
JO - Journal of the American College of Cardiology
JF - Journal of the American College of Cardiology
IS - 4
ER -