TY - JOUR
T1 - Factors associated with improvement in guideline-based use of ICDs in eligible heart failure patients
AU - Mehra, Mandeep R.
AU - Albert, Nancy M.
AU - Curtis, Anne B.
AU - Gheorghiade, Mihai
AU - Heywood, J. Thomas
AU - Liu, Yang
AU - O'Connor, Christopher M.
AU - Reynolds, Dwight
AU - Walsh, Mary Norine
AU - Yancy, Clyde W.
AU - Fonarow, Gregg C.
N1 - Copyright:
Copyright 2012 Elsevier B.V., All rights reserved.
PY - 2012/2
Y1 - 2012/2
N2 - Background: IMPROVE HF, a 24-month performance improvement initiative for outpatient cardiology and multispecialty practices, demonstrated significant improvement in guideline-based use of implantable cardioverter-defibrillators (ICDs) for patients with heart failure (HF). We investigated patient, physician, and practice factors associated with improvements in ICD use. Methods: Patients with HF or postmyocardial infarction (MI) left ventricular systolic dysfunction who met eligibility criteria for ICDs at baseline and 24 months were analyzed. Multivariate analyses were performed to identify patient, physician, and practice characteristics associated with greater improvement in ICD therapy rates from baseline to 24 months. Results: There were 4,058 patients eligible for ICD therapy at baseline and 24 months, with 2,600 (64.1%) treated at baseline and 3,361 (82.8%) treated at 24 months (+18.7%, P < 0.001). Practice heterogeneity in ICD use was significantly decreased after implementation of the performance improvement initiative. Characteristics independently associated with improvement in use of ICD therapy included race, history of MI, presence of edema, QRS duration, months since last measured left ventricular ejection fraction, and number of physicians in the practice. Improvement in ICD use was independent of other patient, physician, and practice characteristics, including age and sex. Conclusions: The IMPROVE HF performance improvement initiative was associated with substantially improved adherence to guideline-recommended ICD therapy. Certain patient and practice characteristics, including race, history of MI, edema, QRS duration, and number of physicians in the practice, were independently associated with improvement in ICD use. These findings highlight the need for ongoing quality improvement monitoring and performance improvement activities.
AB - Background: IMPROVE HF, a 24-month performance improvement initiative for outpatient cardiology and multispecialty practices, demonstrated significant improvement in guideline-based use of implantable cardioverter-defibrillators (ICDs) for patients with heart failure (HF). We investigated patient, physician, and practice factors associated with improvements in ICD use. Methods: Patients with HF or postmyocardial infarction (MI) left ventricular systolic dysfunction who met eligibility criteria for ICDs at baseline and 24 months were analyzed. Multivariate analyses were performed to identify patient, physician, and practice characteristics associated with greater improvement in ICD therapy rates from baseline to 24 months. Results: There were 4,058 patients eligible for ICD therapy at baseline and 24 months, with 2,600 (64.1%) treated at baseline and 3,361 (82.8%) treated at 24 months (+18.7%, P < 0.001). Practice heterogeneity in ICD use was significantly decreased after implementation of the performance improvement initiative. Characteristics independently associated with improvement in use of ICD therapy included race, history of MI, presence of edema, QRS duration, months since last measured left ventricular ejection fraction, and number of physicians in the practice. Improvement in ICD use was independent of other patient, physician, and practice characteristics, including age and sex. Conclusions: The IMPROVE HF performance improvement initiative was associated with substantially improved adherence to guideline-recommended ICD therapy. Certain patient and practice characteristics, including race, history of MI, edema, QRS duration, and number of physicians in the practice, were independently associated with improvement in ICD use. These findings highlight the need for ongoing quality improvement monitoring and performance improvement activities.
KW - evidence-based medicine
KW - heart failure
KW - implantable cardioverter-defibrillator
KW - quality of care
UR - http://www.scopus.com/inward/record.url?scp=84856754275&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84856754275&partnerID=8YFLogxK
U2 - 10.1111/j.1540-8159.2011.03279.x
DO - 10.1111/j.1540-8159.2011.03279.x
M3 - Article
C2 - 22145695
AN - SCOPUS:84856754275
SN - 0147-8389
VL - 35
SP - 135
EP - 145
JO - PACE - Pacing and Clinical Electrophysiology
JF - PACE - Pacing and Clinical Electrophysiology
IS - 2
ER -