TY - JOUR
T1 - Hemophilic bleeding evaluated by blood pool scanning
AU - Green, D.
AU - Spies, S. M.
AU - Rana, N. A.
AU - Milgram, J. W.
AU - Mintzer, R.
PY - 1981/1/1
Y1 - 1981/1/1
N2 - The technique of blood pool scanning was used to examine 15 hemophilic subjects. Employing an in vivo method for erythrocyte labeling with Technetium-99 m, a dynamic perfusion sequence is obtained using a scintillation camera positioned over the area to be examined. This demonstrates the vascularity of the tissue. Subsequently, equilibrium blood pool images of the area are obtained and analyzed with a densitometer to assess relative regional blood volume. In patients who were not bleeding but had chronic arthropathy, vascularity was not increased, and the blood volume of comparable joints was similar. By contrast, marked increases in vascularity and image density were observed in studies of acutely bleeding joints. Chronic hemarthroses were associated with persistent, but less marked increases in joint perfusion. Transient increases in joint vascularity were demonstrated after insertion of knee prostheses. In a patient with a thigh hematoma, the dimensions of the hemorrhage were clearly delineated. Since only a tracer dose of nuclide is infused intravenously, there are no allergic reactions or other side effects of the procedure. Blood pool scanning is a safe, non-invasive technique that augments clinical and radiographic evaluations, and provides a new dimension in the assessment of the hemophilic patient.
AB - The technique of blood pool scanning was used to examine 15 hemophilic subjects. Employing an in vivo method for erythrocyte labeling with Technetium-99 m, a dynamic perfusion sequence is obtained using a scintillation camera positioned over the area to be examined. This demonstrates the vascularity of the tissue. Subsequently, equilibrium blood pool images of the area are obtained and analyzed with a densitometer to assess relative regional blood volume. In patients who were not bleeding but had chronic arthropathy, vascularity was not increased, and the blood volume of comparable joints was similar. By contrast, marked increases in vascularity and image density were observed in studies of acutely bleeding joints. Chronic hemarthroses were associated with persistent, but less marked increases in joint perfusion. Transient increases in joint vascularity were demonstrated after insertion of knee prostheses. In a patient with a thigh hematoma, the dimensions of the hemorrhage were clearly delineated. Since only a tracer dose of nuclide is infused intravenously, there are no allergic reactions or other side effects of the procedure. Blood pool scanning is a safe, non-invasive technique that augments clinical and radiographic evaluations, and provides a new dimension in the assessment of the hemophilic patient.
UR - http://www.scopus.com/inward/record.url?scp=0019512081&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0019512081&partnerID=8YFLogxK
U2 - 10.1055/s-0038-1650171
DO - 10.1055/s-0038-1650171
M3 - Article
C2 - 6269248
AN - SCOPUS:0019512081
SN - 0891-5849
VL - 45
SP - 208
EP - 210
JO - Free Radical Biology and Medicine
JF - Free Radical Biology and Medicine
IS - 3
ER -