T1 - High-resolution myelin-water fraction and quantitative relaxation mapping using 3D ViSTa-MR fingerprinting
AU - Liao, Congyu
AU - Cao, Xiaozhi
AU - Iyer, Siddharth Srinivasan
AU - Schauman, Sophie
AU - Zhou, Zihan
AU - Yan, Xiaoqian
AU - Chen, Quan
AU - Li, Zhitao
AU - Wang, Nan
AU - Gong, Ting
AU - Wu, Zhe
AU - He, Hongjian
AU - Zhong, Jianhui
AU - Yang, Yang
AU - Kerr, Adam
AU - Grill-Spector, Kalanit
AU - Setsompop, Kawin
N1 - Publisher Copyright:
© 2023 International Society for Magnetic Resonance in Medicine.
PY - 2024/6
Y1 - 2024/6
N2 - Purpose: This study aims to develop a high-resolution whole-brain multi-parametric quantitative MRI approach for simultaneous mapping of myelin-water fraction (MWF), T1, T2, and proton-density (PD), all within a clinically feasible scan time. Methods: We developed 3D visualization of short transverse relaxation time component (ViSTa)-MRF, which combined ViSTa technique with MR fingerprinting (MRF), to achieve high-fidelity whole-brain MWF and T1/T2/PD mapping on a clinical 3T scanner. To achieve fast acquisition and memory-efficient reconstruction, the ViSTa-MRF sequence leverages an optimized 3D tiny-golden-angle-shuffling spiral-projection acquisition and joint spatial–temporal subspace reconstruction with optimized preconditioning algorithm. With the proposed ViSTa-MRF approach, high-fidelity direct MWF mapping was achieved without a need for multicompartment fitting that could introduce bias and/or noise from additional assumptions or priors. Results: The in vivo results demonstrate the effectiveness of the proposed acquisition and reconstruction framework to provide fast multi-parametric mapping with high SNR and good quality. The in vivo results of 1 mm- and 0.66 mm-isotropic resolution datasets indicate that the MWF values measured by the proposed method are consistent with standard ViSTa results that are 30× slower with lower SNR. Furthermore, we applied the proposed method to enable 5-min whole-brain 1 mm-iso assessment of MWF and T1/T2/PD mappings for infant brain development and for post-mortem brain samples. Conclusions: In this work, we have developed a 3D ViSTa-MRF technique that enables the acquisition of whole-brain MWF, quantitative T1, T2, and PD maps at 1 and 0.66 mm isotropic resolution in 5 and 15 min, respectively. This advancement allows for quantitative investigations of myelination changes in the brain.
AB - Purpose: This study aims to develop a high-resolution whole-brain multi-parametric quantitative MRI approach for simultaneous mapping of myelin-water fraction (MWF), T1, T2, and proton-density (PD), all within a clinically feasible scan time. Methods: We developed 3D visualization of short transverse relaxation time component (ViSTa)-MRF, which combined ViSTa technique with MR fingerprinting (MRF), to achieve high-fidelity whole-brain MWF and T1/T2/PD mapping on a clinical 3T scanner. To achieve fast acquisition and memory-efficient reconstruction, the ViSTa-MRF sequence leverages an optimized 3D tiny-golden-angle-shuffling spiral-projection acquisition and joint spatial–temporal subspace reconstruction with optimized preconditioning algorithm. With the proposed ViSTa-MRF approach, high-fidelity direct MWF mapping was achieved without a need for multicompartment fitting that could introduce bias and/or noise from additional assumptions or priors. Results: The in vivo results demonstrate the effectiveness of the proposed acquisition and reconstruction framework to provide fast multi-parametric mapping with high SNR and good quality. The in vivo results of 1 mm- and 0.66 mm-isotropic resolution datasets indicate that the MWF values measured by the proposed method are consistent with standard ViSTa results that are 30× slower with lower SNR. Furthermore, we applied the proposed method to enable 5-min whole-brain 1 mm-iso assessment of MWF and T1/T2/PD mappings for infant brain development and for post-mortem brain samples. Conclusions: In this work, we have developed a 3D ViSTa-MRF technique that enables the acquisition of whole-brain MWF, quantitative T1, T2, and PD maps at 1 and 0.66 mm isotropic resolution in 5 and 15 min, respectively. This advancement allows for quantitative investigations of myelination changes in the brain.
KW - high resolution
KW - myelin-water fraction
KW - quantitative MRI
UR - http://www.scopus.com/inward/record.url?scp=85181218302&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85181218302&partnerID=8YFLogxK
U2 - 10.1002/mrm.29990
DO - 10.1002/mrm.29990
M3 - Article
C2 - 38156945
AN - SCOPUS:85181218302
SN - 0740-3194
VL - 91
SP - 2278
EP - 2293
JO - Magnetic resonance in medicine
JF - Magnetic resonance in medicine
IS - 6
ER -