High-resolution myelin-water fraction and quantitative relaxation mapping using 3D ViSTa-MR fingerprinting

Congyu Liao, Xiaozhi Cao*, Siddharth Srinivasan Iyer, Sophie Schauman, Zihan Zhou, Xiaoqian Yan, Quan Chen, Zhitao Li, Nan Wang, Ting Gong, Zhe Wu, Hongjian He, Jianhui Zhong, Yang Yang, Adam Kerr, Kalanit Grill-Spector, Kawin Setsompop

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

Purpose: This study aims to develop a high-resolution whole-brain multi-parametric quantitative MRI approach for simultaneous mapping of myelin-water fraction (MWF), T1, T2, and proton-density (PD), all within a clinically feasible scan time. Methods: We developed 3D visualization of short transverse relaxation time component (ViSTa)-MRF, which combined ViSTa technique with MR fingerprinting (MRF), to achieve high-fidelity whole-brain MWF and T1/T2/PD mapping on a clinical 3T scanner. To achieve fast acquisition and memory-efficient reconstruction, the ViSTa-MRF sequence leverages an optimized 3D tiny-golden-angle-shuffling spiral-projection acquisition and joint spatial–temporal subspace reconstruction with optimized preconditioning algorithm. With the proposed ViSTa-MRF approach, high-fidelity direct MWF mapping was achieved without a need for multicompartment fitting that could introduce bias and/or noise from additional assumptions or priors. Results: The in vivo results demonstrate the effectiveness of the proposed acquisition and reconstruction framework to provide fast multi-parametric mapping with high SNR and good quality. The in vivo results of 1 mm- and 0.66 mm-isotropic resolution datasets indicate that the MWF values measured by the proposed method are consistent with standard ViSTa results that are 30× slower with lower SNR. Furthermore, we applied the proposed method to enable 5-min whole-brain 1 mm-iso assessment of MWF and T1/T2/PD mappings for infant brain development and for post-mortem brain samples. Conclusions: In this work, we have developed a 3D ViSTa-MRF technique that enables the acquisition of whole-brain MWF, quantitative T1, T2, and PD maps at 1 and 0.66 mm isotropic resolution in 5 and 15 min, respectively. This advancement allows for quantitative investigations of myelination changes in the brain.

Original languageEnglish (US)
Pages (from-to)2278-2293
Number of pages16
JournalMagnetic resonance in medicine
Volume91
Issue number6
DOIs
StatePublished - Jun 2024

Keywords

  • high resolution
  • myelin-water fraction
  • quantitative MRI

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'High-resolution myelin-water fraction and quantitative relaxation mapping using 3D ViSTa-MR fingerprinting'. Together they form a unique fingerprint.

Cite this