Identifying Pediatric Severe Sepsis and Septic Shock: Accuracy of Diagnosis Codes

Fran Balamuth, Scott L. Weiss, Matt Hall, Mark I. Neuman, Halden Scott, Patrick W. Brady, Raina Paul, Reid W D Farris, Richard McClead, Sierra Centkowski, Shannon Baumer-Mouradian, Jason Weiser, Katie Hayes, Samir S. Shah, Elizabeth R. Alpern

Research output: Contribution to journalArticlepeer-review

51 Scopus citations

Abstract

OBJECTIVES: To evaluate accuracy of 2 established administrative methods of identifying children with sepsis using a medical record review reference standard.

STUDY DESIGN: Multicenter retrospective study at 6 US children's hospitals. Subjects were children >60 days to <19 years of age and identified in 4 groups based on International Classification of Diseases, Ninth Revision, Clinical Modification codes: (1) severe sepsis/septic shock (sepsis codes); (2) infection plus organ dysfunction (combination codes); (3) subjects without codes for infection, organ dysfunction, or severe sepsis; and (4) infection but not severe sepsis or organ dysfunction. Combination codes were allowed, but not required within the sepsis codes group. We determined the presence of reference standard severe sepsis according to consensus criteria. Logistic regression was performed to determine whether addition of codes for sepsis therapies improved case identification.

RESULTS: A total of 130 out of 432 subjects met reference SD of severe sepsis. Sepsis codes had sensitivity 73% (95% CI 70-86), specificity 92% (95% CI 87-95), and positive predictive value 79% (95% CI 70-86). Combination codes had sensitivity 15% (95% CI 9-22), specificity 71% (95% CI 65-76), and positive predictive value 18% (95% CI 11-27). Slight improvements in model characteristics were observed when codes for vasoactive medications and endotracheal intubation were added to sepsis codes (c-statistic 0.83 vs 0.87, P = .008).

CONCLUSIONS: Sepsis specific International Classification of Diseases, Ninth Revision, Clinical Modification codes identify pediatric patients with severe sepsis in administrative data more accurately than a combination of codes for infection plus organ dysfunction.

Original languageEnglish (US)
Pages (from-to)1295-1300.e4
JournalThe Journal of pediatrics
Volume167
Issue number6
DOIs
StatePublished - Dec 1 2015

ASJC Scopus subject areas

  • Pediatrics, Perinatology, and Child Health

Fingerprint

Dive into the research topics of 'Identifying Pediatric Severe Sepsis and Septic Shock: Accuracy of Diagnosis Codes'. Together they form a unique fingerprint.

Cite this