T1 - Integrated catheter for 3-D intracardiac echocardiography and ultrasound ablation
AU - Gentry, Kenneth L.
AU - Smith, Stephen W.
N1 - Funding Information:
Manuscript received June 20, 2003; accepted March 17, 2004. This research was supported by the NIH (grants HL64962 and HL72840) and the NSF (grant DMR9973801).
PY - 2004/7
Y1 - 2004/7
N2 - A catheter device with integrated ultrasound imaging array and ultrasound ablation transducer is introduced. This device has been designed for use in interventional cardiac procedures in which the cardiac anatomy is first imaged using real-time three-dimensional (3-D) ultrasound, then ablated to treat arrhythmias. The imaging array includes 112 elements operating at 5.4 MHz arranged in a 2-D matrix. Individual elements have a bandwidth of 21% and an insertion loss of 80 dB. The array has an azimuth resolution of 12° and an elevation resolution of 8.7°. The ablation transducer is a concentric piezoelectric transducer PZT-4 ring (outside diameter (O.D.), 4.5 mm, inside diameter (I.D.), 3.1 mm) operating at 10 MHz that surrounds the imaging array. It can produce a spatial-peak, temporal-average intensity up to 16 W/cm 2. The entire device fits into a 9 Fr lumen with a 14 Fr tip to accommodate the ablation ring. With this device we have imaged, in real-time 3-D, a variety of targets including wire phantoms, fixed sheep hearts, and fresh bovine tissue. The ablation ring has been used to heat tissue-mimicking rubber 14°C, as well as create lesions in fresh bovine tissue.
AB - A catheter device with integrated ultrasound imaging array and ultrasound ablation transducer is introduced. This device has been designed for use in interventional cardiac procedures in which the cardiac anatomy is first imaged using real-time three-dimensional (3-D) ultrasound, then ablated to treat arrhythmias. The imaging array includes 112 elements operating at 5.4 MHz arranged in a 2-D matrix. Individual elements have a bandwidth of 21% and an insertion loss of 80 dB. The array has an azimuth resolution of 12° and an elevation resolution of 8.7°. The ablation transducer is a concentric piezoelectric transducer PZT-4 ring (outside diameter (O.D.), 4.5 mm, inside diameter (I.D.), 3.1 mm) operating at 10 MHz that surrounds the imaging array. It can produce a spatial-peak, temporal-average intensity up to 16 W/cm 2. The entire device fits into a 9 Fr lumen with a 14 Fr tip to accommodate the ablation ring. With this device we have imaged, in real-time 3-D, a variety of targets including wire phantoms, fixed sheep hearts, and fresh bovine tissue. The ablation ring has been used to heat tissue-mimicking rubber 14°C, as well as create lesions in fresh bovine tissue.
UR - http://www.scopus.com/inward/record.url?scp=3142671921&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=3142671921&partnerID=8YFLogxK
U2 - 10.1109/TUFFC.2004.1320739
DO - 10.1109/TUFFC.2004.1320739
M3 - Article
C2 - 15300999
AN - SCOPUS:3142671921
SN - 0885-3010
VL - 51
SP - 800
EP - 808
JO - IRE Transactions on Ultrasonic Engineering
JF - IRE Transactions on Ultrasonic Engineering
IS - 7
ER -