T1 - Intraoperative evaluation of acetabular cup position during anterior approach total hip arthroplasty
T2 - are we accurately interpreting?
AU - Delagrammaticas, Dimitri E.
AU - Ochenjele, George
AU - Rosenthal, Brett D.
AU - Assenmacher, Benjamin
AU - Manning, David W.
AU - Stover, Michael D.
PY - 2020/1/1
Y1 - 2020/1/1
N2 - Introduction: Intraoperative radiographic evaluation during total hip arthroplasty (THA) has shown to improve the accuracy of acetabular component placement, however, differences in interpretation based on radiographic technique has not been established. This study aims to determine if differences exist in the interpretation of acetabular component abduction and anteversion between different radiographic projections. Methods: 55 consecutive direct anterior THAs in 49 patients were prospectively enrolled. Target anteversion and abduction was defined by the Lewinnek zone. Fluoroscopy was used to direct acetabular component placement intraoperatively. After final cup implantation, fluoroscopic posterior-anterior hip and pelvis images were obtained for analysis. After completion of the procedure, an anterior-posterior plain pelvis radiograph was obtained in the operating room. Acetabulum component abduction and anteversion were postoperatively determined using specialised software on each of the 3 image acquisition methods. Results: Average acetabular cup abduction for intraoperative fluoroscopic posterior-anterior hip (FH), intraoperative fluoroscopic posterior-anterior pelvis (FP), and postoperative, standard, anteroposterior pelvis radiographs (PP) was 40.95° ± 2.87°, 38.87° ± 3.82° and 41.73° ± 2.96° respectively. The fluoroscopic hip and fluoroscopic pelvis tended to underestimate acetabular cup abduction compared to the postoperative pelvis (p < 0.001). Average acetabular cup anteversion for FH, FP, and PP was 19.89° ± 4.87°, 24.38° ± 5.31° and 13.36° ± 3.52° respectively. Both the fluoroscopic hip and fluoroscopic pelvis overestimated anteversion compared to the AP pelvis, with a 6.38° greater mean value measurement for FH (p < 0.001), and an 11° greater mean value measurement for FP (p < 0.001). Conclusions: Fluoroscopic technique and differences between radiographic projections may result in discrepancies in component position interpretation. Our results support the use of the fluoroscopic posterior-anterior hip as the choice fluoroscopic imaging technique.
AB - Introduction: Intraoperative radiographic evaluation during total hip arthroplasty (THA) has shown to improve the accuracy of acetabular component placement, however, differences in interpretation based on radiographic technique has not been established. This study aims to determine if differences exist in the interpretation of acetabular component abduction and anteversion between different radiographic projections. Methods: 55 consecutive direct anterior THAs in 49 patients were prospectively enrolled. Target anteversion and abduction was defined by the Lewinnek zone. Fluoroscopy was used to direct acetabular component placement intraoperatively. After final cup implantation, fluoroscopic posterior-anterior hip and pelvis images were obtained for analysis. After completion of the procedure, an anterior-posterior plain pelvis radiograph was obtained in the operating room. Acetabulum component abduction and anteversion were postoperatively determined using specialised software on each of the 3 image acquisition methods. Results: Average acetabular cup abduction for intraoperative fluoroscopic posterior-anterior hip (FH), intraoperative fluoroscopic posterior-anterior pelvis (FP), and postoperative, standard, anteroposterior pelvis radiographs (PP) was 40.95° ± 2.87°, 38.87° ± 3.82° and 41.73° ± 2.96° respectively. The fluoroscopic hip and fluoroscopic pelvis tended to underestimate acetabular cup abduction compared to the postoperative pelvis (p < 0.001). Average acetabular cup anteversion for FH, FP, and PP was 19.89° ± 4.87°, 24.38° ± 5.31° and 13.36° ± 3.52° respectively. Both the fluoroscopic hip and fluoroscopic pelvis overestimated anteversion compared to the AP pelvis, with a 6.38° greater mean value measurement for FH (p < 0.001), and an 11° greater mean value measurement for FP (p < 0.001). Conclusions: Fluoroscopic technique and differences between radiographic projections may result in discrepancies in component position interpretation. Our results support the use of the fluoroscopic posterior-anterior hip as the choice fluoroscopic imaging technique.
KW - Acetabular component position
KW - fluoroscopy
KW - hip arthroplasty
KW - radiographic interpretation
UR - http://www.scopus.com/inward/record.url?scp=85070944356&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85070944356&partnerID=8YFLogxK
U2 - 10.1177/1120700019868665
DO - 10.1177/1120700019868665
M3 - Article
C2 - 31387397
AN - SCOPUS:85070944356
SN - 1120-7000
VL - 30
SP - 40
EP - 47
JO - HIP International
JF - HIP International
IS - 1
ER -