Machine learning based quantification of ejection and filling parameters by fully automated dynamic measurement of left ventricular volumes from cardiac magnetic resonance images

Neha Goyal, Victor Mor-Avi, Valentina Volpato, Akhil Narang, Shuo Wang, Michael Salerno, Roberto M. Lang, Amit R. Patel*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

9 Scopus citations

Abstract

Background: Although analysis of cardiac magnetic resonance (CMR) images provides accurate and reproducible measurements of left ventricular (LV) volumes, these measurements are usually not performed throughout the cardiac cycle because of lack of tools that would allow such analysis within a reasonable timeframe. A fully-automated machine-learning (ML) algorithm was recently developed to automatically generate LV volume-time curves. Our aim was to validate ejection and filling parameters calculated from these curves using conventional analysis as a reference. Methods: We studied 21 patients undergoing clinical CMR examinations. LV volume-time curves were obtained using the ML-based algorithm (Neosoft), and independently using slice-by-slice, frame-by-frame manual tracing of the endocardial boundaries. Ejection and filling parameters derived from these curves were compared between the two techniques. For each parameter, Bland-Altman bias and limits of agreement (LOA) were expressed in percent of the mean measured value. Results: Time-volume curves were generated using the automated ML analysis within 2.5 ± 0.5 min, considerably faster than the manual analysis (43 ± 14 min per patient, including ~10 slices with 25–32 frames per slice). Time-volume curves were similar between the two techniques in magnitude and shape. Size and function parameters extracted from these curves showed no significant inter-technique differences, reflected by high correlations, small biases (<10%) and mostly reasonably narrow LOA. Conclusion: ML software for dynamic LV volume measurement allows fast and accurate, fully automated analysis of ejection and filling parameters, compared to manual tracing based analysis. The ability to quickly evaluate time-volume curves is important for a more comprehensive evaluation of the patient's cardiac function.

Original languageEnglish (US)
Pages (from-to)28-32
Number of pages5
JournalMagnetic Resonance Imaging
Volume67
DOIs
StatePublished - Apr 2020

Funding

ARP has received research support from Philips Healthcare and Neosoft . Akhil Narang was funded by a T32 Cardiovascular Sciences Training Grant ( 5T32HL7381 ) from the National Institutes of Health (USA). ARP has received research support from Philips Healthcare and Neosoft. Akhil Narang was funded by a T32 Cardiovascular Sciences Training Grant (5T32HL7381) from the National Institutes of Health (USA).

Keywords

  • Artificial intelligence
  • Left ventricle
  • Time-volume curves

ASJC Scopus subject areas

  • Biophysics
  • Biomedical Engineering
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Machine learning based quantification of ejection and filling parameters by fully automated dynamic measurement of left ventricular volumes from cardiac magnetic resonance images'. Together they form a unique fingerprint.

Cite this