Abstract
In this study, the OptoTrak system was employed to collect the articulating surface measurements of the human knee for the femur, tibia and patella in three experimented specimens. Furthermore. a rigorous mathematical reconstruction procedure that estimates reconstruction error was completed by employed the relative analysis tools. The results show, the measurements for each session were able to reconstruct the three-dimensional calibration to a precision of 0.02mm. On the other word. the OptoTrak can be used to obtain the precise measurements of analytical surface of the human knee joint.
Original language | English (US) |
---|---|
Pages (from-to) | 171-174 |
Number of pages | 4 |
Journal | Biomedical Engineering - Applications, Basis and Communications |
Volume | 14 |
Issue number | 4 |
DOIs | |
State | Published - Aug 25 2002 |
Keywords
- Articulating surface
- Fitting
- Human knee joint
- Measurement