TY - JOUR
T1 - Microwave ablation of hepatic tumors using dual-loop probes
T2 - Results of a phase I clinical trial
AU - Meredith, Kenneth
AU - Lee, Fred
AU - Henry, Mary Beth
AU - Warner, Thomas
AU - Mahvi, David
PY - 2005/12/1
Y1 - 2005/12/1
N2 - Hepatic tumors are a common cause of death worldwide. However, few patients are candidates for resection at the time of presentation. Microwave ablation is a viable alternative available for these patients. To date, only straight antennas are used for microwave ablation. Recently, a prototype loop-shaped microwave antenna was developed that, in animal studies, more effectively kills tumors. For this study, the dual-probe lesions were created by placing the probes in both tumors and normal livers. Lesions were created with 60 watts applied power for 5-7 minutes. The livers were sectioned and stained for viability. The average ablation volume was 63.9 ± 8.7 cm3. Microwave ablation with the loop probes results in complete tumor kill at the ablation/tumor interface, and adjacent to surrounding blood vessels. In addition, vessels within the ablation/tumor interface failed to show viable cells. The shape of the lesions was not distorted by proximity to blood vessels. The advantages of this configuration over conventional straight probes include the ability to encircle a tumor, deliver large amounts of precisely targeted microwave energy to the tumor, and spare normal liver outside the loop.
AB - Hepatic tumors are a common cause of death worldwide. However, few patients are candidates for resection at the time of presentation. Microwave ablation is a viable alternative available for these patients. To date, only straight antennas are used for microwave ablation. Recently, a prototype loop-shaped microwave antenna was developed that, in animal studies, more effectively kills tumors. For this study, the dual-probe lesions were created by placing the probes in both tumors and normal livers. Lesions were created with 60 watts applied power for 5-7 minutes. The livers were sectioned and stained for viability. The average ablation volume was 63.9 ± 8.7 cm3. Microwave ablation with the loop probes results in complete tumor kill at the ablation/tumor interface, and adjacent to surrounding blood vessels. In addition, vessels within the ablation/tumor interface failed to show viable cells. The shape of the lesions was not distorted by proximity to blood vessels. The advantages of this configuration over conventional straight probes include the ability to encircle a tumor, deliver large amounts of precisely targeted microwave energy to the tumor, and spare normal liver outside the loop.
KW - Hepatic carcinoma
KW - Loop microwave probe
KW - Microwave ablation
KW - Radiofrequency ablation
UR - http://www.scopus.com/inward/record.url?scp=28644448608&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=28644448608&partnerID=8YFLogxK
U2 - 10.1016/j.gassur.2005.07.028
DO - 10.1016/j.gassur.2005.07.028
M3 - Article
C2 - 16332494
AN - SCOPUS:28644448608
SN - 1091-255X
VL - 9
SP - 1354
EP - 1360
JO - Journal of Gastrointestinal Surgery
JF - Journal of Gastrointestinal Surgery
IS - 9
ER -