TY - JOUR
T1 - Multiscale aspects of generation of high-gamma activity during seizures in human neocortex
AU - Eissa, Tahra L.
AU - Tryba, Andrew K.
AU - Marcuccilli, Charles J.
AU - Ben-Mabrouk, Faiza
AU - Smith, Elliot H.
AU - Lew, Sean M.
AU - Goodman, Robert R.
AU - McKhann, Guy M.
AU - Frim, David M.
AU - Pesce, Lorenzo L.
AU - Kohrman, Michael H.
AU - Emerson, Ronald G.
AU - Schevon, Catherine A.
AU - van Drongelen, Wim
N1 - Publisher Copyright:
© 2016 Eissa et al.
PY - 2016
Y1 - 2016
N2 - High-gamma (HG; 80-150 Hz) activity in macroscopic clinical records is considered a marker for critical brain regions involved in seizure initiation; it is correlated with pathological multiunit firing during neocortical seizures in the seizure core, an area identified by correlated multiunit spiking and low frequency seizure activity. However, the effects of the spatiotemporal dynamics of seizure on HG power generation are not well understood. Here, we studied HG generation and propagation, using a three-step, multiscale signal analysis and modeling approach. First, we analyzed concurrent neuronal and microscopic network HG activity in neocortical slices from seven intractable epilepsy patients. We found HG activity in these networks, especially when neurons displayed paroxysmal depolarization shifts and network activity was highly synchronized. Second, we examined HG activity acquired with microelectrode arrays recorded during human seizures (n = 8). We confirmed the presence of synchronized HG power across microelectrode records and the macroscale, both specifically associated with the core region of the seizure. Third, we used volume conduction-based modeling to relate HG activity and network synchrony at different network scales. We showed that local HG oscillations require high levels of synchrony to cross scales, and that this requirement is met at the microscopic scale, but not within macroscopic networks. Instead, we present evidence that HG power at the macroscale may result from harmonics of ongoing seizure activity. Ictal HG power marks the seizure core, but the generating mechanism can differ across spatial scales.
AB - High-gamma (HG; 80-150 Hz) activity in macroscopic clinical records is considered a marker for critical brain regions involved in seizure initiation; it is correlated with pathological multiunit firing during neocortical seizures in the seizure core, an area identified by correlated multiunit spiking and low frequency seizure activity. However, the effects of the spatiotemporal dynamics of seizure on HG power generation are not well understood. Here, we studied HG generation and propagation, using a three-step, multiscale signal analysis and modeling approach. First, we analyzed concurrent neuronal and microscopic network HG activity in neocortical slices from seven intractable epilepsy patients. We found HG activity in these networks, especially when neurons displayed paroxysmal depolarization shifts and network activity was highly synchronized. Second, we examined HG activity acquired with microelectrode arrays recorded during human seizures (n = 8). We confirmed the presence of synchronized HG power across microelectrode records and the macroscale, both specifically associated with the core region of the seizure. Third, we used volume conduction-based modeling to relate HG activity and network synchrony at different network scales. We showed that local HG oscillations require high levels of synchrony to cross scales, and that this requirement is met at the microscopic scale, but not within macroscopic networks. Instead, we present evidence that HG power at the macroscale may result from harmonics of ongoing seizure activity. Ictal HG power marks the seizure core, but the generating mechanism can differ across spatial scales.
UR - http://www.scopus.com/inward/record.url?scp=85021858529&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85021858529&partnerID=8YFLogxK
U2 - 10.1523/ENEURO.0141-15.2016
DO - 10.1523/ENEURO.0141-15.2016
M3 - Article
C2 - 27257623
AN - SCOPUS:85021858529
SN - 2373-2822
VL - 3
SP - 281
EP - 290
JO - eNeuro
JF - eNeuro
IS - 2
ER -