TY - JOUR
T1 - Multisite evaluation of the bd max extended enteric bacterial panel for detection of yersinia enterocolitica, enterotoxigenic Escherichia coli, vibrio, and plesiomonas shigelloides from stool specimens
AU - Simner, Patricia J.
AU - Oethinger, Margret
AU - Stellrecht, Kathleen A.
AU - Pillai, Dylan R.
AU - Yogev, Ram
AU - Leblond, Helene
AU - Mortensen, Joel
PY - 2017/11
Y1 - 2017/11
N2 - The purpose of this study was to perform a multisite evaluation to establish the performance characteristics of the BD Max extended enteric bacterial panel (xEBP) assay directly from unpreserved or Cary-Blair-preserved stool specimens for the detection of Yersinia enterocolitica, enterotoxigenic Escherichia coli (ETEC), Vibrio, and Plesiomonas shigelloides. The study included prospective, retrospective, and prepared contrived specimens from 6 clinical sites. BD Max xEBP results were compared to the reference method, which included standard culture techniques coupled with alternate PCR and sequencing, except for ETEC, for which the reference method was two alternate PCRs and sequencing. Alternate PCR was also used to confirm the historical results for the retrospective specimens and for discrepant result analysis. A total of 2,410 unformed, deidentified stool specimens were collected. The prevalence in the prospective samples as defined by the reference method was 1.2% ETEC, 0.1% Vibrio, 0% Y. enterocolitica, and 0% P. shigelloides. Compared to the reference method, the positive percent agreement (PPA) (95% confidence interval [CI]), negative percent agreement (NPA) (95% CI), and kappa coefficient (95% CI) for the BD Max xEBP assay for all specimens combined were as follows: ETEC, 97.6% (87.4 to 99.6), 99.8% (99.5 to 99.9), and 0.93 (0.87 to 0.99); Vibrio, 100% (96.4 to 100), 99.7% (99.4 to 99.8), and 0.96 (0.93 to 0.99); Y. enterocolitica, 99.0% (94.8 to 99.8), 99.9% (99.8 to 99.9), and 0.99 (0.98 to 1); P. shigelloides, 100% (96.4 to 100), 99.8% (99.5 to 99.9), and 0.98 (0.95 to 1), respectively. In this multicenter study, the BD Max xEBP showed a high correlation (kappa, 0.97; 95% CI, 0.95 to 0.98) with the conventional methods for the detection of ETEC, Vibrio, Y. enterocolitica, and P. shigelloides in stool specimens from patients suspected of acute gastroenteritis, enteritis, or colitis.
AB - The purpose of this study was to perform a multisite evaluation to establish the performance characteristics of the BD Max extended enteric bacterial panel (xEBP) assay directly from unpreserved or Cary-Blair-preserved stool specimens for the detection of Yersinia enterocolitica, enterotoxigenic Escherichia coli (ETEC), Vibrio, and Plesiomonas shigelloides. The study included prospective, retrospective, and prepared contrived specimens from 6 clinical sites. BD Max xEBP results were compared to the reference method, which included standard culture techniques coupled with alternate PCR and sequencing, except for ETEC, for which the reference method was two alternate PCRs and sequencing. Alternate PCR was also used to confirm the historical results for the retrospective specimens and for discrepant result analysis. A total of 2,410 unformed, deidentified stool specimens were collected. The prevalence in the prospective samples as defined by the reference method was 1.2% ETEC, 0.1% Vibrio, 0% Y. enterocolitica, and 0% P. shigelloides. Compared to the reference method, the positive percent agreement (PPA) (95% confidence interval [CI]), negative percent agreement (NPA) (95% CI), and kappa coefficient (95% CI) for the BD Max xEBP assay for all specimens combined were as follows: ETEC, 97.6% (87.4 to 99.6), 99.8% (99.5 to 99.9), and 0.93 (0.87 to 0.99); Vibrio, 100% (96.4 to 100), 99.7% (99.4 to 99.8), and 0.96 (0.93 to 0.99); Y. enterocolitica, 99.0% (94.8 to 99.8), 99.9% (99.8 to 99.9), and 0.99 (0.98 to 1); P. shigelloides, 100% (96.4 to 100), 99.8% (99.5 to 99.9), and 0.98 (0.95 to 1), respectively. In this multicenter study, the BD Max xEBP showed a high correlation (kappa, 0.97; 95% CI, 0.95 to 0.98) with the conventional methods for the detection of ETEC, Vibrio, Y. enterocolitica, and P. shigelloides in stool specimens from patients suspected of acute gastroenteritis, enteritis, or colitis.
KW - BD Max
KW - Enteric pathogens
KW - Enterotoxigenic Escherichia coli
KW - Extended enteric bacterial panel
KW - Gastrointestinal panel
KW - Multiplex PCR
KW - Plesiomonas shigelloides
KW - Vibrio
KW - Yersinia enterocolitica
UR - http://www.scopus.com/inward/record.url?scp=85032436508&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85032436508&partnerID=8YFLogxK
U2 - 10.1128/JCM.00911-17
DO - 10.1128/JCM.00911-17
M3 - Article
C2 - 28878009
AN - SCOPUS:85032436508
SN - 0095-1137
VL - 55
SP - 3258
EP - 3266
JO - Journal of clinical microbiology
JF - Journal of clinical microbiology
IS - 11
ER -