TY - GEN
T1 - Passive split ring resonator for continuous physiological sensing through conductivity measurements
AU - Baker, Evan
AU - Shaw, Noah
AU - Wang, Chen
AU - Zhang, Hao
AU - Sun, Cheng
PY - 2013
Y1 - 2013
N2 - The Split Ring Resonator (SRR) has been developed and explored for a number of sensing technologies and devices. A SRR can be equivalently regarded as an LC circuit; changes in the dielectric environment will change the equivalent capacitance of the resonator, resulting in a shift of the resonant frequency as well as the quality factor (Q-factor).This makes the device a promising application for continuous personal health monitoring throughout the day. In this work, we are developing a passive radio frequency sensor based on ring resonator designs. The targeted frequency band is within 2.4- 2.5GHz ISM (Industrial-Scientific-Medical radio band) and is available for medical devices. The resonator structure is first simulated using Finite Difference Time Domain (FDTD) method by CST Microwave Studio to determine the resonant frequency. Then for the experimental study, a microstrip transmission line with a double split ring resonator (DSRR) was fabricated on a printed circuit board (PCB) with biocompatible PVC coating on top. Tuning the thickness and material of the biocompatible coating can further improve the biocompatibility, Q-factor, and resulting sensitivity (mS) of the device. Reflection spectrum (S11) is measured using a network analyzer at 100 mW. The current design senses changes in conductivity down to 0.5 mS. By reducing coating thickness, reducing the spacing between resonators, and with more efficient resonator designs we expect to further improve this sensitivity. This sensor could be utilized by either implanted into the interstitial layer beneath the skin or embedded into a contact lens to sense tear salinity levels.
AB - The Split Ring Resonator (SRR) has been developed and explored for a number of sensing technologies and devices. A SRR can be equivalently regarded as an LC circuit; changes in the dielectric environment will change the equivalent capacitance of the resonator, resulting in a shift of the resonant frequency as well as the quality factor (Q-factor).This makes the device a promising application for continuous personal health monitoring throughout the day. In this work, we are developing a passive radio frequency sensor based on ring resonator designs. The targeted frequency band is within 2.4- 2.5GHz ISM (Industrial-Scientific-Medical radio band) and is available for medical devices. The resonator structure is first simulated using Finite Difference Time Domain (FDTD) method by CST Microwave Studio to determine the resonant frequency. Then for the experimental study, a microstrip transmission line with a double split ring resonator (DSRR) was fabricated on a printed circuit board (PCB) with biocompatible PVC coating on top. Tuning the thickness and material of the biocompatible coating can further improve the biocompatibility, Q-factor, and resulting sensitivity (mS) of the device. Reflection spectrum (S11) is measured using a network analyzer at 100 mW. The current design senses changes in conductivity down to 0.5 mS. By reducing coating thickness, reducing the spacing between resonators, and with more efficient resonator designs we expect to further improve this sensitivity. This sensor could be utilized by either implanted into the interstitial layer beneath the skin or embedded into a contact lens to sense tear salinity levels.
UR - http://www.scopus.com/inward/record.url?scp=84903484170&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84903484170&partnerID=8YFLogxK
U2 - 10.1115/IMECE2013-66744
DO - 10.1115/IMECE2013-66744
M3 - Conference contribution
AN - SCOPUS:84903484170
SN - 9780791856390
T3 - ASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE)
BT - Micro- and Nano-Systems Engineering and Packaging
PB - American Society of Mechanical Engineers (ASME)
T2 - ASME 2013 International Mechanical Engineering Congress and Exposition, IMECE 2013
Y2 - 15 November 2013 through 21 November 2013
ER -