Preparatory intravascular stenting technique: An easier method of supermicrosurgical lymphaticovenular anastomosis

Takashi Nuri*, Koichi Ueda, Akira Yamada, Mai Hara

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

13 Scopus citations

Abstract

Recent supermicrosurgical techniques have made it possible to anastomose lymph vessels to the subdermal venular system. However, because the lymphatic fluid is clear and the vessel is translucent, soft, and fragile, with a thinner wall than blood vessels, supermicrosurgical lymphaticovenular anastomosis is a demanding technique. One difficulty of lymphaticovenular anastomosis is identification of the lumen to pass the suture into it. This report describes a preparatory intravascular stenting technique to identify the lumen and perform lymphaticovenular anastomosis accurately. In this technique, we placed 9-0 or 10-0 nylon thread into the lymphatic lumen before transecting the lymph vessel. The end of the nylon was pushed through to appear from the lymphatic lumen, then advanced into the vein to stabilize the 2 vessels. This technique allows supermicrosurgical lymphaticovenular anastomosis to be performed quickly and efficiently.

Original languageEnglish (US)
Pages (from-to)541-543
Number of pages3
JournalAnnals of plastic surgery
Volume71
Issue number5
DOIs
StatePublished - Nov 2013

Keywords

  • Preparatory intravascular stenting technique
  • lymphaticovenular anastomosis
  • lymphedema
  • supermicrosurgery

ASJC Scopus subject areas

  • Surgery

Fingerprint

Dive into the research topics of 'Preparatory intravascular stenting technique: An easier method of supermicrosurgical lymphaticovenular anastomosis'. Together they form a unique fingerprint.

Cite this