Prospective side by side comparison of outcomes and complications with a simple versus intensive anticoagulation monitoring strategy in pediatric extracorporeal life support patients

Jane S. Yu, Ryan P. Barbaro, Donald A. Granoski, Mary E. Bauman, M. Patricia Massicotte, Laurance L. Lequier, Gail M. Annich, Lindsay M. Ryerson

Research output: Contribution to journalArticlepeer-review

16 Scopus citations

Abstract

Objectives: A continuous infusion of unfractionated heparin is the most common anticoagulant used for pediatric patients on extracorporeal life support. The objective of this study was to compare extracorporeal life support complications and outcomes between two large-volume pediatric extracorporeal life support centers that use different anticoagulation strategies. Design: Prospective, observational cohort study. Setting: The University of Michigan used simple anticoagulation monitoring, whereas the University of Alberta used an intensive anticoagulation monitoring strategy. Patients: Pediatric patients on extracorporeal life support. Interventions: None. Measurements and Main Results: The primary outcome measure was major bleeding per extracorporeal life support run defined as bleeding that was retroperitoneal, pulmonary, or involved the CNS; bleeding greater than 20 mL/kg over 24 hours; or bleeding that required surgical intervention. Secondary outcomes measured were patient thrombosis per run, circuit thrombosis per run, and survival to hospital discharge per patient. Eighty-eight patients (95 runs) less than 18 years old were enrolled at the two centers over 2 years. The two centers enrolled different extracorporeal life support populations; University of Alberta enrolled more postcardiac surgical patients (74% vs 47%; p = 0.005). The indication for extracorporeal life support support also varied by center (p = 0.04). The two centers used similar proportions of VA extracorporeal life support (p = 0.3). Median (interquartile range) unfractionated heparin doses were similar between University of Michigan and University of Alberta, 30 (21-34) U/kg/hr and 26 (22-31) U/kg/hr, p value equals to 0.3, respectively. Median (interquartile range) antifactor Xa was lower in the University of Michigan cohort (0.23 [0.19-0.28] vs 0.41 [0.36-0.46] U/mL; p < 0.001). There was no significant difference in major bleeding (15% University of Michigan vs 21% University of Alberta; p = 0.6) or in patient thromboses (18% University of Michigan vs 13% University of Alberta; p = 0.5). There was no significant difference in survival to hospital discharge (University of Michigan 63% vs University of Alberta 73%; p = 0.1). Conclusions: Although this prospective cohort study compared different pediatric extracorporeal life support populations, the results did not identify a significant difference in outcomes between simple and intensive anticoagulation monitoring strategies.

Original languageEnglish (US)
Pages (from-to)1055-1062
Number of pages8
JournalPediatric Critical Care Medicine
Volume18
Issue number11
DOIs
StatePublished - Nov 2017
Externally publishedYes

Keywords

  • Anticoagulation
  • Extracorporeal life support
  • Hemorrhage
  • Heparin
  • Pediatrics

ASJC Scopus subject areas

  • Critical Care and Intensive Care Medicine
  • Pediatrics, Perinatology, and Child Health

Fingerprint

Dive into the research topics of 'Prospective side by side comparison of outcomes and complications with a simple versus intensive anticoagulation monitoring strategy in pediatric extracorporeal life support patients'. Together they form a unique fingerprint.

Cite this