TY - JOUR
T1 - Protein detection using arrayed microsensor chips
T2 - Tuning sensor footprint to achieve ultrasensitive readout of CA-125 in serum and whole blood
AU - Das, Jagotamoy
AU - Kelley, Shana O.
PY - 2011/2/15
Y1 - 2011/2/15
N2 - Multiplexed assays that can measure protein biomarkers and internal standards are highly desirable given the potential to reduce false positives and negatives. We report here the use of a chip-based platform that achieves multiplexed immunosensing of the ovarian cancer biomarker CA-125 without the need for covalent labeling or sandwich complexes. The sensor chips allow the straightforward comparison of detectors of different sizes, and we used this feature to scan the microscale size regime for the best sensor size and optimize the limit of detection exhibited down to 0.1 U/mL. The assay has a straightforward design, with readout being performed in a single step involving the introduction of a noncovalently attached redox reporter group. The detection system reported exhibits excellent specificity, with analysis of a specific cancer biomarker, CA-125, performed in human serum and whole blood. The multiplexing of the system allows the analysis of the biomarker to be performed in parallel with an abundant serum protein for internal calibration.
AB - Multiplexed assays that can measure protein biomarkers and internal standards are highly desirable given the potential to reduce false positives and negatives. We report here the use of a chip-based platform that achieves multiplexed immunosensing of the ovarian cancer biomarker CA-125 without the need for covalent labeling or sandwich complexes. The sensor chips allow the straightforward comparison of detectors of different sizes, and we used this feature to scan the microscale size regime for the best sensor size and optimize the limit of detection exhibited down to 0.1 U/mL. The assay has a straightforward design, with readout being performed in a single step involving the introduction of a noncovalently attached redox reporter group. The detection system reported exhibits excellent specificity, with analysis of a specific cancer biomarker, CA-125, performed in human serum and whole blood. The multiplexing of the system allows the analysis of the biomarker to be performed in parallel with an abundant serum protein for internal calibration.
UR - http://www.scopus.com/inward/record.url?scp=79951615475&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79951615475&partnerID=8YFLogxK
U2 - 10.1021/ac102917f
DO - 10.1021/ac102917f
M3 - Article
C2 - 21244005
AN - SCOPUS:79951615475
SN - 0003-2700
VL - 83
SP - 1167
EP - 1172
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 4
ER -