TY - JOUR
T1 - Psychiatric functioning and quality of life in younǵ patients with cardiac rhythm devices
AU - Webster, Gregory
AU - Panek, Kathryn A.
AU - Labella, Madelyn
AU - Taylor, George Alexander
AU - Gauvreau, Kimberlee
AU - Cecchin, Frank
AU - Martuscello, Maria
AU - Walsh, Edward P.
AU - Berul, Charles I.
AU - DeMaso, David R.
PY - 2014/4
Y1 - 2014/4
N2 - BACKGROUND: Less is known about depression, anxiety and quality of life (QoL) in children and adolescents with pacemakers (PMs) and implantable cardioverter-defibrillators (ICDs) than is known in adults with these devices. METHODS: A standardized psychiatric interview diagnosed anxiety/ depressive disorders in a cross-sectional study. Self-report measures of anxiety, depression and post-traumatic stress disorder were obtained. Medical disease severity, family functioning and QoL data were collected. A total of 166 patients were enrolled (52 ICD, 114 PM; median age 15 years). RESULTS: Prevalence of current and lifetime psychiatric disorders was higher in patients with ICDs than PMs (Current: 27% vs. 11%, P 5 .02; Lifetime: 52% ICD vs. 34% PM, P 5 .01). Patients with ICDs had more anxiety than a healthy population (25% vs. 7%, P < .01). Patients with ICDs and PMs had similar levels of depression as a healthy population (ICD 10%, PM 4%, reference 4%, P 5 .29). In multivariate analysis including a medical disease score, demographics, exposure to betablockers, activity limitations, hospitalizations, shocks and procedures, the type of device (PM versus ICD) did not predict psychiatric diagnoses when age at implantation and the severity of medical disease were controlled for. Patients with ICDs and PMs had lower physical QoL scores (ICD 45, PM 47.5, Norm 53, P ≤ .03), but similar psychosocial functioning scores (ICD 49, PM 51, Norm 51, P ≤ .16) versus a normal reference population. CONCLUSIONS: Anxiety is highly prevalent in young patients with ICDs, but the higher rates can be attributed to medical disease severity and age at implantation instead of type of device.
AB - BACKGROUND: Less is known about depression, anxiety and quality of life (QoL) in children and adolescents with pacemakers (PMs) and implantable cardioverter-defibrillators (ICDs) than is known in adults with these devices. METHODS: A standardized psychiatric interview diagnosed anxiety/ depressive disorders in a cross-sectional study. Self-report measures of anxiety, depression and post-traumatic stress disorder were obtained. Medical disease severity, family functioning and QoL data were collected. A total of 166 patients were enrolled (52 ICD, 114 PM; median age 15 years). RESULTS: Prevalence of current and lifetime psychiatric disorders was higher in patients with ICDs than PMs (Current: 27% vs. 11%, P 5 .02; Lifetime: 52% ICD vs. 34% PM, P 5 .01). Patients with ICDs had more anxiety than a healthy population (25% vs. 7%, P < .01). Patients with ICDs and PMs had similar levels of depression as a healthy population (ICD 10%, PM 4%, reference 4%, P 5 .29). In multivariate analysis including a medical disease score, demographics, exposure to betablockers, activity limitations, hospitalizations, shocks and procedures, the type of device (PM versus ICD) did not predict psychiatric diagnoses when age at implantation and the severity of medical disease were controlled for. Patients with ICDs and PMs had lower physical QoL scores (ICD 45, PM 47.5, Norm 53, P ≤ .03), but similar psychosocial functioning scores (ICD 49, PM 51, Norm 51, P ≤ .16) versus a normal reference population. CONCLUSIONS: Anxiety is highly prevalent in young patients with ICDs, but the higher rates can be attributed to medical disease severity and age at implantation instead of type of device.
KW - Anxiety
KW - Depression
KW - ICD
KW - Pacemaker
KW - Pediatrics
UR - http://www.scopus.com/inward/record.url?scp=84898719614&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84898719614&partnerID=8YFLogxK
U2 - 10.1542/peds.2013-1394
DO - 10.1542/peds.2013-1394
M3 - Article
C2 - 24664095
AN - SCOPUS:84898719614
SN - 0031-4005
VL - 133
SP - e964-e972
JO - Pediatrics
JF - Pediatrics
IS - 4
ER -