TY - JOUR
T1 - Radiological Medical Device Innovation
T2 - Approvals via the Premarket Approval Pathway From 2000 to 2015
AU - Ghobadi, Comeron W.
AU - Hayman, Emily L.
AU - Finkle, Joshua H.
AU - Walter, Jessica R.
AU - Xu, Shuai
N1 - Publisher Copyright:
© 2016 American College of Radiology
PY - 2017/1/1
Y1 - 2017/1/1
N2 - Purpose The aim of this study was to critically assess the clinical evidence leading to radiologic medical device approvals via the premarket approval pathway from 2000 to 2015. Methods This study used the publically available FDA premarket database for radiologic device approvals over the past 15 years (September 1, 2000, to August 31, 2015). Approval characteristics were collected for each device, and statistical analysis was performed on the data for each pivotal trial. Additionally, methodological quality of the pivotal trial was determined using the Quality Assessment of Diagnostic Accuracy Studies tool. Results Twenty-three class III radiologic device approvals were identified, with breast imaging accounting for 16 (70%) and computer-aided detection software accounting for 9 (39%) approvals. The median premarket approval time was 475 days (range, 180-1,116). Twenty-one devices were approved on the basis of multireader, multicenter studies, one on the basis of a randomized controlled trial, and one on the basis of a preclinical technical equivalence trial. The median number of patients per pivotal trial was 201 (range, 25-3,946). Twenty-six of the 34 pivotal trials (76%) had at least one methodologic bias. Breast imaging devices had a greater number of patients per pivotal trial (P =.009) and more prospective studies. With regard to all modalities, increased time to device approval correlated with weaker trial quality (r = 0.600, P <.001). Conclusions Radiologic devices are largely approved by multireader, multicenter studies, the recommended standard for assessing diagnostic technologies. Given that radiologic devices play a key role in modern medicine, further efforts should be made to increase transparency of clinical data leading to approval.
AB - Purpose The aim of this study was to critically assess the clinical evidence leading to radiologic medical device approvals via the premarket approval pathway from 2000 to 2015. Methods This study used the publically available FDA premarket database for radiologic device approvals over the past 15 years (September 1, 2000, to August 31, 2015). Approval characteristics were collected for each device, and statistical analysis was performed on the data for each pivotal trial. Additionally, methodological quality of the pivotal trial was determined using the Quality Assessment of Diagnostic Accuracy Studies tool. Results Twenty-three class III radiologic device approvals were identified, with breast imaging accounting for 16 (70%) and computer-aided detection software accounting for 9 (39%) approvals. The median premarket approval time was 475 days (range, 180-1,116). Twenty-one devices were approved on the basis of multireader, multicenter studies, one on the basis of a randomized controlled trial, and one on the basis of a preclinical technical equivalence trial. The median number of patients per pivotal trial was 201 (range, 25-3,946). Twenty-six of the 34 pivotal trials (76%) had at least one methodologic bias. Breast imaging devices had a greater number of patients per pivotal trial (P =.009) and more prospective studies. With regard to all modalities, increased time to device approval correlated with weaker trial quality (r = 0.600, P <.001). Conclusions Radiologic devices are largely approved by multireader, multicenter studies, the recommended standard for assessing diagnostic technologies. Given that radiologic devices play a key role in modern medicine, further efforts should be made to increase transparency of clinical data leading to approval.
KW - 21st Century Cures Act
KW - FDA
KW - Medical device innovation
KW - National Evaluation System for Health Technology
KW - health policy
KW - innovation
KW - medical device regulation
KW - patient safety
UR - http://www.scopus.com/inward/record.url?scp=85009063732&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85009063732&partnerID=8YFLogxK
U2 - 10.1016/j.jacr.2016.08.014
DO - 10.1016/j.jacr.2016.08.014
M3 - Article
C2 - 28061962
AN - SCOPUS:85009063732
SN - 1546-1440
VL - 14
SP - 24
EP - 33
JO - Journal of the American College of Radiology
JF - Journal of the American College of Radiology
IS - 1
ER -