Reproducibility of tricuspid regurgitant jet velocity measurements in children and young adults with sickle cell disease undergoing screening for pulmonary hypertension

Robert I Liem, Luciana T Young, Amy Shah D Lay, Stephanie A. Pelligra, Richard J. Labotka, Alexis A Thompson

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

The reproducibility of tricuspid regurgitant jet velocity (TRJV) measurements by Doppler echocardiography has not been subjected to systematic evaluation among individuals with sickle cell disease (SCD) undergoing screening for pulmonary hypertension. We examined sources of disagreement associated with peak TRJV in children and young adults with SCD. Peak TRJV was independently measured and interpreted a week apart by separate sonographers and readers, respectively, in 30 subjects (mean age, 15.8 ± 3.3 years) who provided 120 observations. We assessed intra-/inter-reader, intra-/inter-sonographer, sonographer-reader, and within subject agreement using Intraclass Correlation Coefficient (ICC) and Cohen's kappa (κ). Agreement was examined graphically using Bland-Altman plots. Although sonographers could estimate and measure peak TRJV in all subjects, readers designated tricuspid regurgitation nonquantifiable in 10-17% of their final interpretations. Intra-reader agreement was highest (ICC = 0.93 [95% CI 0.86, 0.97], P = 0.0001) and within subject agreement lowest (ICC = 0.36 [95% CI 0.02, 0.64], P = 0.021) for single TRJV measurements. Similarly, intra-reader agreement was highest (κ = 0.74 [95% CI 0.53, 0.95], P = 0.0001) and within subject lowest (κ = 0.14 [95% CI 20.17, 0.46], P = 0.38) when sonographers and readers categorized TRJV measurements. On Bland-Altman plots, absolute differences in observations increased with higher mean TRJV readings for intra-/inter-reader agreement. Peak TRJV measurements in individual children and young adults with SCD are affected by several sources of disagreement, underscoring the need for methodological improvements that ensure reproducibility of this screening modality for making clinical decisions in this population.

Original languageEnglish (US)
Pages (from-to)741-745
Number of pages5
JournalAmerican Journal of Hematology
Volume85
Issue number10
DOIs
StatePublished - Jan 1 2010

Fingerprint

Sickle Cell Anemia
Pulmonary Hypertension
Young Adult
Tricuspid Valve Insufficiency
Doppler Echocardiography
Reading
Population

ASJC Scopus subject areas

  • Hematology

Cite this

@article{35101b9b09cc47198eda7fa7a2c26305,
title = "Reproducibility of tricuspid regurgitant jet velocity measurements in children and young adults with sickle cell disease undergoing screening for pulmonary hypertension",
abstract = "The reproducibility of tricuspid regurgitant jet velocity (TRJV) measurements by Doppler echocardiography has not been subjected to systematic evaluation among individuals with sickle cell disease (SCD) undergoing screening for pulmonary hypertension. We examined sources of disagreement associated with peak TRJV in children and young adults with SCD. Peak TRJV was independently measured and interpreted a week apart by separate sonographers and readers, respectively, in 30 subjects (mean age, 15.8 ± 3.3 years) who provided 120 observations. We assessed intra-/inter-reader, intra-/inter-sonographer, sonographer-reader, and within subject agreement using Intraclass Correlation Coefficient (ICC) and Cohen's kappa (κ). Agreement was examined graphically using Bland-Altman plots. Although sonographers could estimate and measure peak TRJV in all subjects, readers designated tricuspid regurgitation nonquantifiable in 10-17{\%} of their final interpretations. Intra-reader agreement was highest (ICC = 0.93 [95{\%} CI 0.86, 0.97], P = 0.0001) and within subject agreement lowest (ICC = 0.36 [95{\%} CI 0.02, 0.64], P = 0.021) for single TRJV measurements. Similarly, intra-reader agreement was highest (κ = 0.74 [95{\%} CI 0.53, 0.95], P = 0.0001) and within subject lowest (κ = 0.14 [95{\%} CI 20.17, 0.46], P = 0.38) when sonographers and readers categorized TRJV measurements. On Bland-Altman plots, absolute differences in observations increased with higher mean TRJV readings for intra-/inter-reader agreement. Peak TRJV measurements in individual children and young adults with SCD are affected by several sources of disagreement, underscoring the need for methodological improvements that ensure reproducibility of this screening modality for making clinical decisions in this population.",
author = "Liem, {Robert I} and Young, {Luciana T} and Lay, {Amy Shah D} and Pelligra, {Stephanie A.} and Labotka, {Richard J.} and Thompson, {Alexis A}",
year = "2010",
month = "1",
day = "1",
doi = "10.1002/ajh.21793",
language = "English (US)",
volume = "85",
pages = "741--745",
journal = "American Journal of Hematology",
issn = "0361-8609",
publisher = "Wiley-Liss Inc.",
number = "10",

}

TY - JOUR

T1 - Reproducibility of tricuspid regurgitant jet velocity measurements in children and young adults with sickle cell disease undergoing screening for pulmonary hypertension

AU - Liem, Robert I

AU - Young, Luciana T

AU - Lay, Amy Shah D

AU - Pelligra, Stephanie A.

AU - Labotka, Richard J.

AU - Thompson, Alexis A

PY - 2010/1/1

Y1 - 2010/1/1

N2 - The reproducibility of tricuspid regurgitant jet velocity (TRJV) measurements by Doppler echocardiography has not been subjected to systematic evaluation among individuals with sickle cell disease (SCD) undergoing screening for pulmonary hypertension. We examined sources of disagreement associated with peak TRJV in children and young adults with SCD. Peak TRJV was independently measured and interpreted a week apart by separate sonographers and readers, respectively, in 30 subjects (mean age, 15.8 ± 3.3 years) who provided 120 observations. We assessed intra-/inter-reader, intra-/inter-sonographer, sonographer-reader, and within subject agreement using Intraclass Correlation Coefficient (ICC) and Cohen's kappa (κ). Agreement was examined graphically using Bland-Altman plots. Although sonographers could estimate and measure peak TRJV in all subjects, readers designated tricuspid regurgitation nonquantifiable in 10-17% of their final interpretations. Intra-reader agreement was highest (ICC = 0.93 [95% CI 0.86, 0.97], P = 0.0001) and within subject agreement lowest (ICC = 0.36 [95% CI 0.02, 0.64], P = 0.021) for single TRJV measurements. Similarly, intra-reader agreement was highest (κ = 0.74 [95% CI 0.53, 0.95], P = 0.0001) and within subject lowest (κ = 0.14 [95% CI 20.17, 0.46], P = 0.38) when sonographers and readers categorized TRJV measurements. On Bland-Altman plots, absolute differences in observations increased with higher mean TRJV readings for intra-/inter-reader agreement. Peak TRJV measurements in individual children and young adults with SCD are affected by several sources of disagreement, underscoring the need for methodological improvements that ensure reproducibility of this screening modality for making clinical decisions in this population.

AB - The reproducibility of tricuspid regurgitant jet velocity (TRJV) measurements by Doppler echocardiography has not been subjected to systematic evaluation among individuals with sickle cell disease (SCD) undergoing screening for pulmonary hypertension. We examined sources of disagreement associated with peak TRJV in children and young adults with SCD. Peak TRJV was independently measured and interpreted a week apart by separate sonographers and readers, respectively, in 30 subjects (mean age, 15.8 ± 3.3 years) who provided 120 observations. We assessed intra-/inter-reader, intra-/inter-sonographer, sonographer-reader, and within subject agreement using Intraclass Correlation Coefficient (ICC) and Cohen's kappa (κ). Agreement was examined graphically using Bland-Altman plots. Although sonographers could estimate and measure peak TRJV in all subjects, readers designated tricuspid regurgitation nonquantifiable in 10-17% of their final interpretations. Intra-reader agreement was highest (ICC = 0.93 [95% CI 0.86, 0.97], P = 0.0001) and within subject agreement lowest (ICC = 0.36 [95% CI 0.02, 0.64], P = 0.021) for single TRJV measurements. Similarly, intra-reader agreement was highest (κ = 0.74 [95% CI 0.53, 0.95], P = 0.0001) and within subject lowest (κ = 0.14 [95% CI 20.17, 0.46], P = 0.38) when sonographers and readers categorized TRJV measurements. On Bland-Altman plots, absolute differences in observations increased with higher mean TRJV readings for intra-/inter-reader agreement. Peak TRJV measurements in individual children and young adults with SCD are affected by several sources of disagreement, underscoring the need for methodological improvements that ensure reproducibility of this screening modality for making clinical decisions in this population.

UR - http://www.scopus.com/inward/record.url?scp=77957689401&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77957689401&partnerID=8YFLogxK

U2 - 10.1002/ajh.21793

DO - 10.1002/ajh.21793

M3 - Article

C2 - 20652966

AN - SCOPUS:77957689401

VL - 85

SP - 741

EP - 745

JO - American Journal of Hematology

JF - American Journal of Hematology

SN - 0361-8609

IS - 10

ER -