TY - JOUR
T1 - Shock absorption during transtibial amputee gait
T2 - Does longitudinal prosthetic stiffness play a role?
AU - Boutwell, Erin
AU - Stine, Rebecca
AU - Gard, Steven
N1 - Publisher Copyright:
© 2016, © The International Society for Prosthetics and Orthotics 2016.
PY - 2017/4/1
Y1 - 2017/4/1
N2 - Background: Reduced-stiffness components are often prescribed in lower-limb prostheses, but their efficacy in augmenting shock absorption has been inconclusive. Objectives: To perform a systematic variation of longitudinal prosthetic stiffness over a wide range of values and to evaluate its effect on shock absorption during gait. Study design: Repeated-measures crossover experiment. Methods: Twelve subjects with a unilateral transtibial amputation walked at normal and fast self-selected speeds. Longitudinal prosthetic stiffness was modified by springs within a shock-absorbing pylon: normal (manufacturer recommended), 75% of normal (medium), 50% of normal (soft), and rigid (displacement blocked). The variables of interest were kinematic (stance-phase knee flexion and pelvic obliquity) and kinetic (prosthetic-side ground reaction force loading peak magnitude and timing). Results: No changes were observed in kinematic measures during gait. A significant difference in peak ground reaction force magnitudes between medium and normal (p = 0.001) during freely selected walking was attributed to modified walking speed (p = 0.008). Ground reaction force peaks were found to be statistically different during fast walking, but only between isolated stiffness conditions. Thus, altering longitudinal prosthesis stiffness produced no appreciable change in gait biomechanics. Conclusion: Prosthesis stiffness does not appear to substantially influence shock absorption in transtibial prosthesis users. Clinical relevance: Varying the level of longitudinal prosthesis stiffness did not meaningfully influence gait biomechanics at self-selected walking speeds. Thus, as currently prescribed within a transtibial prosthesis, adding longitudinal stiffness in isolation may not provide the anticipated shock absorption benefits. Further research into residual limb properties and compensatory mechanisms is needed.
AB - Background: Reduced-stiffness components are often prescribed in lower-limb prostheses, but their efficacy in augmenting shock absorption has been inconclusive. Objectives: To perform a systematic variation of longitudinal prosthetic stiffness over a wide range of values and to evaluate its effect on shock absorption during gait. Study design: Repeated-measures crossover experiment. Methods: Twelve subjects with a unilateral transtibial amputation walked at normal and fast self-selected speeds. Longitudinal prosthetic stiffness was modified by springs within a shock-absorbing pylon: normal (manufacturer recommended), 75% of normal (medium), 50% of normal (soft), and rigid (displacement blocked). The variables of interest were kinematic (stance-phase knee flexion and pelvic obliquity) and kinetic (prosthetic-side ground reaction force loading peak magnitude and timing). Results: No changes were observed in kinematic measures during gait. A significant difference in peak ground reaction force magnitudes between medium and normal (p = 0.001) during freely selected walking was attributed to modified walking speed (p = 0.008). Ground reaction force peaks were found to be statistically different during fast walking, but only between isolated stiffness conditions. Thus, altering longitudinal prosthesis stiffness produced no appreciable change in gait biomechanics. Conclusion: Prosthesis stiffness does not appear to substantially influence shock absorption in transtibial prosthesis users. Clinical relevance: Varying the level of longitudinal prosthesis stiffness did not meaningfully influence gait biomechanics at self-selected walking speeds. Thus, as currently prescribed within a transtibial prosthesis, adding longitudinal stiffness in isolation may not provide the anticipated shock absorption benefits. Further research into residual limb properties and compensatory mechanisms is needed.
KW - Biomechanics of prosthetic/orthotic devices
KW - gait analysis
KW - testing of prosthetic and orthotic components
UR - http://www.scopus.com/inward/record.url?scp=85018775160&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85018775160&partnerID=8YFLogxK
U2 - 10.1177/0309364616640945
DO - 10.1177/0309364616640945
M3 - Article
C2 - 27117010
AN - SCOPUS:85018775160
SN - 0309-3646
VL - 41
SP - 178
EP - 185
JO - Prosthetics and orthotics international
JF - Prosthetics and orthotics international
IS - 2
ER -