TY - JOUR
T1 - Short-term deployment of self-expanding metallic stents facilitates healing of bronchial dehiscence
AU - Mughal, Majid M.
AU - Gildea, Thomas R.
AU - Murthy, Sudish
AU - Pettersson, Gosta
AU - DeCamp, Malcom
AU - Mehta, Atul C.
PY - 2005/9/15
Y1 - 2005/9/15
N2 - Bronchial dehiscence after lung transplantation is difficult to treat and associated with high mortality. We describe our experience using self-expanding metallic stents to treat post-lung transplant bronchial dehiscence. From January 1995 to June 2004, 189 single and 118 double lung transplants were performed in our institution, totaling 425 at-risk bronchial anastomoses. Seven (1.6%) incidents of life-threatening bronchial dehiscence were treated with self-expanding metallic stents. The interval between transplant and diagnosis of dehiscence was 29.1 ± 18.5 days. All patients presented with respiratory distress, and three required mechanical ventilation. Self-expanding metallic stent placement resulted in complete bronchial healing. All three patients with respiratory failure requiring mechanical ventilation were successfully weaned after stent placement. In two later cases, the stents were electively removed after adequate healing of the dehiscence. Complications included stent migration (one patient) and in-stent stenosis (three patients). Two of these patients required repeat stent insertion after removal, due to bronchomalacia. In patients with life-threatening bronchial dehiscence, self-expanding metallic stents offer prospects for a successful outcome. Self-expanding metallic stents are known to be associated with significant granulation tissue formation, and this property provides a platform for healing of dehiscence and, in time, peribronchial soft tissue grows in to cover the defect, allowing stent removal.
AB - Bronchial dehiscence after lung transplantation is difficult to treat and associated with high mortality. We describe our experience using self-expanding metallic stents to treat post-lung transplant bronchial dehiscence. From January 1995 to June 2004, 189 single and 118 double lung transplants were performed in our institution, totaling 425 at-risk bronchial anastomoses. Seven (1.6%) incidents of life-threatening bronchial dehiscence were treated with self-expanding metallic stents. The interval between transplant and diagnosis of dehiscence was 29.1 ± 18.5 days. All patients presented with respiratory distress, and three required mechanical ventilation. Self-expanding metallic stent placement resulted in complete bronchial healing. All three patients with respiratory failure requiring mechanical ventilation were successfully weaned after stent placement. In two later cases, the stents were electively removed after adequate healing of the dehiscence. Complications included stent migration (one patient) and in-stent stenosis (three patients). Two of these patients required repeat stent insertion after removal, due to bronchomalacia. In patients with life-threatening bronchial dehiscence, self-expanding metallic stents offer prospects for a successful outcome. Self-expanding metallic stents are known to be associated with significant granulation tissue formation, and this property provides a platform for healing of dehiscence and, in time, peribronchial soft tissue grows in to cover the defect, allowing stent removal.
KW - Bronchial dehiscence
KW - Lung transplantation
KW - Metallic stents
UR - http://www.scopus.com/inward/record.url?scp=24944508070&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=24944508070&partnerID=8YFLogxK
U2 - 10.1164/rccm.200410-1388OC
DO - 10.1164/rccm.200410-1388OC
M3 - Article
C2 - 15937290
AN - SCOPUS:24944508070
SN - 1073-449X
VL - 172
SP - 768
EP - 771
JO - American journal of respiratory and critical care medicine
JF - American journal of respiratory and critical care medicine
IS - 6
ER -