Simulation of intramuscular EMG signal detection using implantable myoelectric sensors

Madeleine M. Lowery*, Richard F. Weir, Todd A Kuiken

*Corresponding author for this work

Research output: Contribution to conferencePaper

2 Scopus citations

Abstract

The volume conduction of intramuscular EMG signals recorded using implanted electrodes was examined using model simulation. Local effects due to electrode geometry, material properties including fibrocollagenous encapsulation tissue, and electrode orientation were investigated. Muscle fiber and motor unit action potentials were simulated using two different volume conductor models -a finite element (FE) model that was used to explore the influence of the surrounding tissue properties, and an analytical infinite volume conductor model, used to explore the approximate pick-up volume of the electrode. The amplitude of simulated action potentials progressively increased as the conducting electrode poles, non-conducting electrode casing and highly resistive encapsulation tissue were added to the model. The pick-up volume of the electrode was estimated by simulating muscle fiber action potentials from 20,000 muscle fibers randomly located throughout the muscle. Changing the orientation of the electrode with respect to the fiber direction reduced the selectivity of the electrode and altered the shape of the pick-up volume. As the angle of rotation was increased from 0° to 22.5° and 45°, the pick-up volume of the electrode and the shape of the surrounding isopotential contours became progressively wider and flatter. The estimated pick-up range of the IMES electrode, assuming a cylindrical muscle, was 4.8 mm, 6.2 mm and 7.5 mm for electrode orientations of 0°, 22.5° and 45°, respectively.

Original languageEnglish (US)
Pages360-363
Number of pages4
DOIs
StatePublished - Dec 1 2005
Event2nd International IEEE EMBS Conference on Neural Engineering, 2005 - Arlington, VA, United States
Duration: Mar 16 2005Mar 19 2005

Other

Other2nd International IEEE EMBS Conference on Neural Engineering, 2005
CountryUnited States
CityArlington, VA
Period3/16/053/19/05

Keywords

  • EMG
  • Finite element
  • Implanted electrode
  • Model
  • Prosthesis
  • Volume conduction

ASJC Scopus subject areas

  • Engineering(all)

Fingerprint Dive into the research topics of 'Simulation of intramuscular EMG signal detection using implantable myoelectric sensors'. Together they form a unique fingerprint.

  • Cite this

    Lowery, M. M., Weir, R. F., & Kuiken, T. A. (2005). Simulation of intramuscular EMG signal detection using implantable myoelectric sensors. 360-363. Paper presented at 2nd International IEEE EMBS Conference on Neural Engineering, 2005, Arlington, VA, United States. https://doi.org/10.1109/CNE.2005.1419632