Static Versus Expandable Polyether Ether Ketone (PEEK) Interbody Cages: A Comparison of One-Year Clinical and Radiographic Outcomes for One-Level Transforaminal Lumbar Interbody Fusion

Jose A. Canseco, Brian A. Karamian*, Stephen L. DiMaria, Parthik D. Patel, Srikanth N. Divi, Michael Chang, Tyler Timmons, Lovy Grewal, Haydn Hallman, Joseph K. Lee, I. David Kaye, Barrett I. Woods, Mark F. Kurd, D. Greg Anderson, Jeffrey A. Rihn, Alan S. Hilibrand, Christopher K. Kepler, Alexander R. Vaccaro, Gregory D. Schroeder

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

2 Scopus citations

Abstract

Objective: To examine the effect of static versus expandable polyether ether ketone (PEEK) cages on both clinical and radiographic outcomes. Methods: A retrospective cohort study was conducted on patients who underwent one-level transforaminal lumbar interbody fusion with either a static or expandable PEEK cage. Patient outcomes were obtained from chart review and radiographic outcomes were measured using standing, lateral radiographs. Recovery ratios and the proportion of patients achieving the minimally clinically important difference were calculated for Oswestry Disability Index (ODI), Physical Component Score-12, Mental Component Score-12, visual analogue scale for back, and visual analogue scale for leg at 1 year and compared between groups. Multivariate linear regression analysis was performed to determine the effect of cage type on the change in patient-reported outcome measures, controlling for demographic factors. Results: A total of 240 patients (137 static, 103 expandable) were included in the final analysis. ΔPhysical Component Score-12 scores at 3 months were significantly greater for the static group (16.0 vs. 10.0, P = 0.043) compared with the expandable group. Multivariate regression demonstrated that use of an expandable cage was associated with greater improvements in ΔODI (β: –7.82, P = 0.048) at 1 year. No differences were found in the perioperative change in sagittal spinal alignment within or between groups at 1 year. Subsidence rates failed to show any statistically significant difference between the 2 groups. Conclusions: Transforaminal lumbar interbody fusion with an expandable PEEK cage is an independent predictor of improved ODI scores at 1 year. Our study showed no significant differences in subsidence rates or changes in sagittal spinal alignment between static and expandable PEEK cages.

Original languageEnglish (US)
Pages (from-to)e492-e501
JournalWorld neurosurgery
Volume152
DOIs
StatePublished - Aug 2021

Keywords

  • Expandable cage
  • Lumbar fusion
  • PEEK
  • Patient-reported outcomes
  • Static cage
  • TLIF

ASJC Scopus subject areas

  • Surgery
  • Clinical Neurology

Fingerprint

Dive into the research topics of 'Static Versus Expandable Polyether Ether Ketone (PEEK) Interbody Cages: A Comparison of One-Year Clinical and Radiographic Outcomes for One-Level Transforaminal Lumbar Interbody Fusion'. Together they form a unique fingerprint.

Cite this