TY - JOUR
T1 - The impact of pre-implant illness severity on the outcomes of pediatric patients undergoing durable ventricular assist device
AU - Butto, Arene
AU - Teele, Sarah A.
AU - Sleeper, Lynn A.
AU - Thrush, Philip T.
AU - Philip, Joseph
AU - Lu, Minmin
AU - Cantor, Ryan S.
AU - Rossano, Joseph W.
N1 - Funding Information:
Data collection for this research effort was supported, in part, by the NHLBI, National Institutes of Health, Department of Health and Human Services under Contract No. HHSN268201100025C. Data analysis was performed at Boston Children's Hospital.
Publisher Copyright:
© 2020 International Society for Heart and Lung Transplantation
PY - 2020/7
Y1 - 2020/7
N2 - BACKGROUND: Durable ventricular assist devices (VADs) are increasingly used to treat children with heart failure. Studies demonstrate worse outcomes for those in cardiogenic shock at the time of VAD, but limited data exist on less acutely ill children. We describe the association between illness severity and outcomes in this population. METHODS: Data were analyzed from 373 children (aged <19 years) receiving durable VADs from 46 centers in the Pediatric Interagency Registry for Mechanical Circulatory Support. Outcomes were compared by Interagency Registry for Mechanical Circulatory Support (INTERMACS) Patient Profile (PP) and pre-implant characteristics using competing risks methodology. RESULTS: Analyses identified 97 patients in cardiogenic shock (PP 1), 222 with progressive decline (PP 2), and 42 stable on inotropes (PP 3). There were 39 infants, 124 were aged 1 to 9 years and 210 were aged 10 to 19 years. A majority had cardiomyopathy and 66 had congenital heart disease (CHD). There were 224 (62%) continuous-flow VADs. Before implant, 40% received mechanical ventilation (MV). Within 6 months post-implant, 57% underwent transplant and 14% died. PP 1 mortality was highest (25% vs 10% for PP 2, hazard ratio [HR]: 2.5, 95% CI: 1.4–4.4, p = 0.02). In PP 1, CHD was an independent mortality risk factor (HR: 2.9, 95% CI: 1.1–7.8, p = 0.03). In PP 2, pulsatile VADs were associated with death (HR: 3.9, 95% CI: 1.6–9.5, p = 0.003). Patients on MV had high mortality (20%–30%) across PP 1 to PP 3 (HR: 3.0 vs no MV, p < 0.001). CONCLUSIONS: Children in shock at the time of VAD implant have poor outcomes. MV is associated with increased mortality even in lower acuity INTERMACS profiles. Further study is needed to identify modifiable risk factors in this population.
AB - BACKGROUND: Durable ventricular assist devices (VADs) are increasingly used to treat children with heart failure. Studies demonstrate worse outcomes for those in cardiogenic shock at the time of VAD, but limited data exist on less acutely ill children. We describe the association between illness severity and outcomes in this population. METHODS: Data were analyzed from 373 children (aged <19 years) receiving durable VADs from 46 centers in the Pediatric Interagency Registry for Mechanical Circulatory Support. Outcomes were compared by Interagency Registry for Mechanical Circulatory Support (INTERMACS) Patient Profile (PP) and pre-implant characteristics using competing risks methodology. RESULTS: Analyses identified 97 patients in cardiogenic shock (PP 1), 222 with progressive decline (PP 2), and 42 stable on inotropes (PP 3). There were 39 infants, 124 were aged 1 to 9 years and 210 were aged 10 to 19 years. A majority had cardiomyopathy and 66 had congenital heart disease (CHD). There were 224 (62%) continuous-flow VADs. Before implant, 40% received mechanical ventilation (MV). Within 6 months post-implant, 57% underwent transplant and 14% died. PP 1 mortality was highest (25% vs 10% for PP 2, hazard ratio [HR]: 2.5, 95% CI: 1.4–4.4, p = 0.02). In PP 1, CHD was an independent mortality risk factor (HR: 2.9, 95% CI: 1.1–7.8, p = 0.03). In PP 2, pulsatile VADs were associated with death (HR: 3.9, 95% CI: 1.6–9.5, p = 0.003). Patients on MV had high mortality (20%–30%) across PP 1 to PP 3 (HR: 3.0 vs no MV, p < 0.001). CONCLUSIONS: Children in shock at the time of VAD implant have poor outcomes. MV is associated with increased mortality even in lower acuity INTERMACS profiles. Further study is needed to identify modifiable risk factors in this population.
KW - cardiomyopathy
KW - congenital heart disease
KW - heart failure
KW - mechanical circulatory support
KW - pediatrics
KW - ventricular assist device
UR - http://www.scopus.com/inward/record.url?scp=85081279678&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85081279678&partnerID=8YFLogxK
U2 - 10.1016/j.healun.2020.02.011
DO - 10.1016/j.healun.2020.02.011
M3 - Article
C2 - 32165048
AN - SCOPUS:85081279678
SN - 1053-2498
VL - 39
SP - 666
EP - 674
JO - Journal of Heart and Lung Transplantation
JF - Journal of Heart and Lung Transplantation
IS - 7
ER -