The use of intracardiac echocardiography during percutaneous pulmonary valve replacement

Sawsan M. Awad*, Syed Asif Masood, Ismael Gonzalez, Qi Ling Cao, Raid Abdulla, Mary G. Heitschmidt, Ziyad M. Hijazi

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

33 Scopus citations

Abstract

High-quality live imaging assessment of cardiac valves and cardiac anatomy is crucial for the success of catheter-based procedures. We present our experience using Intracardiac echocardiography (ICE) during transcatheter Percutaneous Pulmonary Valve replacement (tPVR).This is a retrospective study that included 35 patients who underwent tPVR between April 2008 and June 2012. Thirty-one of these patients had the procedure performed under continuous ICE guidance. Pre-procedure transthoracic echocardiography (TTE) was obtained in all patients. ICE was performed at baseline, during the procedure, and at the conclusion of the procedure. Comparisons between the pre-procedure TTE and baseline ICE data and between post-procedure ICE data and the following day TTE were performed. Total of 35 patients had tPVR during the above-mentioned time period. Twenty-one patients received the Edwards Sapien valve and 14 patients had the Melody valve. Thirty-one patients had the procedure performed under continuous ICE guidance. The mean Pre-TTE peak gradient (PG) and Pre-ICE-PG were 45.5 ± 20 vs 33 ± 13 mmHg (p <0.001) and the mean Pre-TTE mean gradient (MG) and Pre-ICE-MG were 27.7 ± 13 vs 21 ± 18 mmHg (p < 0.001). The mean Post-TTE- PG and Post-ICE-PGwere 24.3 ± 11vs 15.3 ± 7 mmHg(p < 0.001) and the mean of the Post-TTE-MG and Post-ICE-MG were 14.2 ± 7 vs 8.4 ± 4 mmHg (p < 0.001). There was a good correlation between peak ICE and TTE gradient at baseline and after valve placement. For the degree of pulmonary regurgitation, there was no significant difference between TTE and ICE. ICE is an important modality to guide tPVR in patients with dysfunctional homograft valve between the right ventricle and pulmonary artery and should be used to assess valve function before, during and immediately after the procedure.

Original languageEnglish (US)
Pages (from-to)76-83
Number of pages8
JournalPediatric cardiology
Volume36
Issue number1
DOIs
StatePublished - Jan 2015

Keywords

  • Edwards Sapien valve
  • Intracardiac echocardiography (ICE)
  • Melody valve
  • Percutaneous pulmonary valve placement

ASJC Scopus subject areas

  • Pediatrics, Perinatology, and Child Health
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'The use of intracardiac echocardiography during percutaneous pulmonary valve replacement'. Together they form a unique fingerprint.

Cite this