Theoretical and experimental study on the detection limit of the micro-ring resonator based ultrasound point detectors

Youngseop Lee, Qiangzhou Rong, Ki Hee Song, David A. Czaplewski, Hao F. Zhang, Junjie Yao*, Cheng Sun*

*Corresponding author for this work

Research output: Contribution to journalLetterpeer-review

4 Scopus citations

Abstract

Combining the diffusive laser excitation and the photoacoustic signals detection, photoacoustic computed tomography (PACT) is uniquely suited for deep tissue imaging. A diffraction-limited ultrasound point detector is highly desirable for maximizing the spatial resolution and the field-of-view of the reconstructed volumetric images. Among all the available ultrasound detectors, micro-ring resonator (MRR) based ultrasound detectors offer the lowest area-normalized limit of detection (nLOD) in a miniature form-factor, making it an ideal candidate as an ultrasound point detector. However, despite their wide adoption for photoacoustic imaging, the underlying signal transduction process has not been systematically studied yet. Here we report a comprehensive theoretical model capturing the transduction of incident acoustic signals into digital data, and the associated noise propagation process, using experimentally calibrated key process parameters. The theoretical model quantifies the signal-to-noise ratio (SNR) and the nLOD under the influence of the key process variables, including the quality factor (Q-factor) of the MRR and the driving wavelength. While asserting the need for higher Q-factors, the theoretical model further quantifies the optimal driving wavelength for optimizing the nLOD. Given the MRR with a Q-factor of 1 × 105, the theoretical model predicts an optimal SNR of 30.1 dB and a corresponding nLOD of 3.75 × 10−2 mPa mm2/Hz1/2, which are in good agreement with the experimental measurements of 31.0 dB and 3.39 × 10−2 mPa mm2/Hz1/2, respectively. The reported theoretical model can be used in guiding the optimization of MRR-based ultrasonic detectors and PA experimental conditions, in attaining higher imaging resolution and contrast. The optimized operating condition has been further validated by performing PACT imaging of a human hair phantom.

Original languageEnglish (US)
Article number100574
JournalPhotoacoustics
Volume34
DOIs
StatePublished - Dec 2023

Funding

This work was supported by the grants P41GM135018 and R01GM143397 from the US National Institutes of Health to H.F.Z. and C.S.; the grants R01EB028143 , R01NS111039 , RF1NS115581 , and R01HL166522 from the US National Institutes of Health , CAREER award 2144788 from the US National Science Foundation , and 226178 from the Chan Zuckerberg Initiative , all to J.Y.. Work performed at the Center for Nanoscale Materials, a U.S. Department of Energy Office of Science User Facility, was supported by the U.S. DOE , Office of Basic Energy Sciences, under Contract No. DE-AC02-06CH11357 .

Keywords

  • Photoacoustic computed tomography
  • Photoacoustic imaging
  • Polymer micro-ring resonator
  • Ultrasound detector

ASJC Scopus subject areas

  • Atomic and Molecular Physics, and Optics
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Theoretical and experimental study on the detection limit of the micro-ring resonator based ultrasound point detectors'. Together they form a unique fingerprint.

Cite this