Three-dimensional echo-shifted EPI with simultaneous blip-up and blip-down acquisitions for correcting geometric distortion

Kaibao Sun, Zhifeng Chen, Guangyu Dan, Qingfei Luo, Lirong Yan, Feng Liu, Xiaohong Joe Zhou*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: EPI with blip-up/down acquisition (BUDA) can provide high-quality images with minimal distortions by using two readout trains with opposing phase-encoding gradients. Because of the need for two separate acquisitions, BUDA doubles the scan time and degrades the temporal resolution when compared to single-shot EPI, presenting a major challenge for many applications, particularly fMRI. This study aims at overcoming this challenge by developing an echo-shifted EPI BUDA (esEPI-BUDA) technique to acquire both blip-up and blip-down datasets in a single shot. Methods: A 3D esEPI-BUDA pulse sequence was designed by using an echo-shifting strategy to produce two EPI readout trains. These readout trains produced a pair of k-space datasets whose k-space trajectories were interleaved with opposite phase-encoding gradient directions. The two k-space datasets were separately reconstructed using a 3D SENSE algorithm, from which time-resolved B0-field maps were derived using TOPUP in FSL and then input into a forward model of joint parallel imaging reconstruction to correct for geometric distortion. In addition, Hankel structured low-rank constraint was incorporated into the reconstruction framework to improve image quality by mitigating the phase errors between the two interleaved k-space datasets. Results: The 3D esEPI-BUDA technique was demonstrated in a phantom and an fMRI study on healthy human subjects. Geometric distortions were effectively corrected in both phantom and human brain images. In the fMRI study, the visual activation volumes and their BOLD responses were comparable to those from conventional 3D echo-planar images. Conclusion: The improved imaging efficiency and dynamic distortion correction capability afforded by 3D esEPI-BUDA are expected to benefit many EPI applications.

Original languageEnglish (US)
Pages (from-to)2375-2387
Number of pages13
JournalMagnetic resonance in medicine
Volume90
Issue number6
DOIs
StatePublished - Dec 2023

Funding

This work was supported in part by the National Institutes of Health (NIH) under award numbers 5R01EB026716 and 1S10RR028898. ZC and LY are supported by NIH Grants R01NS118019 and RF1AG072490. The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIH or the other funding agencies. The authors are grateful to Drs. Kezhou Wang, Alessandro Scotti, and Muge Karaman for helpful discussions.

Keywords

  • 3D EPI
  • Echo shifting
  • Hankel low-rank reconstruction
  • blip-up and blip-down acquisitions (BUDA)
  • fMRI
  • geometric distortion correction

ASJC Scopus subject areas