T1 - Using micropower impulse radar technology to screen for pneumothorax
T2 - An international bi-institutional study
AU - Van Der Wilden, Gwen
AU - Albers, Christof
AU - Haefeli, Peter
AU - Zimmerman, Heinz
AU - Exadaktylos, Aris
AU - Levy, Phillip
AU - Birkham, Oscar
AU - Michailidou, Maria
AU - Sideris, Antonios
AU - Velmahos, George
AU - Alam, Hasan
AU - King, David
AU - Fagenholz, Peter
AU - Yeh, Dante
AU - De Moya, Marc A.
N1 - Copyright:
Copyright 2013 Elsevier B.V., All rights reserved.
PY - 2012/12
Y1 - 2012/12
N2 - BACKGROUND: Pneumothoraces (PTXs) are a common entity in thoracic trauma. Micropower impulse radar (MIR) has been able to detect PTXs in surgical patients. However, this technology has not been tested previously on trauma patients. The purpose of this study was to determine the sensitivity and specificity of MIR to detect clinically significant PTXs. We hypothesized that MIR technology can effectively screen trauma patients for clinically significant PTXs. METHODS: This was a prospective observational study in Level I trauma centers in Boston, Massachusetts, and Bern, Switzerland. All trauma patients undergoing a chest computed tomographic (CT) scan were eligible for the study. Consent was obtained, and readings were performed within 30 minutes before or after the CT scan. The patients had eight lung fields tested (four on each side). The qualitative and quantitative MIR results were blinded and stored on the device. We then compared the results of the MIR to the CT scan and the need for chest tube drainage. We defined PTXs as clinically significant if they required a chest tube. RESULTS: Seventy-five patients were enrolled, with a mean age of 46 ± 16 years. Eighty-four percent were male. The screening test took approximately 1 minute. All but two patients had blunt chest trauma. Six true-positives, 6 false-positives, 63 true-negatives, and 0 false-negatives resulted in an overall sensitivity of 100%. CONCLUSION: MIR is an easy to use handheld technology that effectively screened patients for clinically significant PTXs, with a sensitivity and negative predictive value of 100%. MIR may be used for rapid, repeatable, and ongoing surveillance of trauma patients. LEVEL OF EVIDENCE: Diagnostic study, level III.
AB - BACKGROUND: Pneumothoraces (PTXs) are a common entity in thoracic trauma. Micropower impulse radar (MIR) has been able to detect PTXs in surgical patients. However, this technology has not been tested previously on trauma patients. The purpose of this study was to determine the sensitivity and specificity of MIR to detect clinically significant PTXs. We hypothesized that MIR technology can effectively screen trauma patients for clinically significant PTXs. METHODS: This was a prospective observational study in Level I trauma centers in Boston, Massachusetts, and Bern, Switzerland. All trauma patients undergoing a chest computed tomographic (CT) scan were eligible for the study. Consent was obtained, and readings were performed within 30 minutes before or after the CT scan. The patients had eight lung fields tested (four on each side). The qualitative and quantitative MIR results were blinded and stored on the device. We then compared the results of the MIR to the CT scan and the need for chest tube drainage. We defined PTXs as clinically significant if they required a chest tube. RESULTS: Seventy-five patients were enrolled, with a mean age of 46 ± 16 years. Eighty-four percent were male. The screening test took approximately 1 minute. All but two patients had blunt chest trauma. Six true-positives, 6 false-positives, 63 true-negatives, and 0 false-negatives resulted in an overall sensitivity of 100%. CONCLUSION: MIR is an easy to use handheld technology that effectively screened patients for clinically significant PTXs, with a sensitivity and negative predictive value of 100%. MIR may be used for rapid, repeatable, and ongoing surveillance of trauma patients. LEVEL OF EVIDENCE: Diagnostic study, level III.
KW - micropower impulse radar
KW - Pneumothorax
KW - trauma
UR - http://www.scopus.com/inward/record.url?scp=84871218720&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84871218720&partnerID=8YFLogxK
U2 - 10.1097/TA.0b013e318270bbe4
DO - 10.1097/TA.0b013e318270bbe4
M3 - Article
C2 - 23188233
AN - SCOPUS:84871218720
SN - 2163-0755
VL - 73
SP - 1418
EP - 1421
JO - Journal of Trauma and Acute Care Surgery
JF - Journal of Trauma and Acute Care Surgery
IS - 6
ER -