Validation of a novel wearable electromyography patch for monitoring submental muscle activity during swallowing: A randomized crossover trial

Cagla Kantarcigil, Min Ku Kim, Taehoo Chang, Bruce A. Craig, Anne Smith, Chi Hwan Lee, Georgia A. Malandraki*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

18 Scopus citations

Abstract

Purpose: Surface electromyography (sEMG) is often used for biofeedback during swallowing rehabilitation. However, commercially available sEMG electrodes are not optimized for the head and neck area, have rigid form, and are mostly available in large medical centers. We developed an ultrathin, soft, and flexible sEMG patch, specifically designed to conform to the submental anatomy and which will be ultimately incorporated into a telehealth system. To validate this firstgeneration sEMG patch, we compared its safety, efficiency, and signal quality in monitoring submental muscle activity with that of widely used conventional sEMG electrodes. Method: A randomized crossover design was used to compare the experimental sEMG patch with conventional (snap-on) sEMG electrodes. Participants completed the same experimental protocol with both electrodes in counterbalanced order. Swallow trials included five trials of 5-and 10-ml water. Comparisons were made on (a) signalrelated factors: signal-to-noise ratio (SNR), baseline amplitude, normalized mean amplitude, and sEMG burst duration and (b) safety/preclinical factors: safety/adverse effects, efficiency of electrode placement, and satisfaction/ comfort. Noninferiority and equivalence tests were used to examine signal-related factors. Paired t tests and descriptive statistics were used to examine safety/preclinical factors.Results: Forty healthy adults participated (24 women, Mage = 67.5 years). Signal-related factors: SNR of the experimental patch was not inferior to the SNR of the conventional electrodes (p < .0056). Similarly, baseline amplitude obtained with the experimental patch was not inferior to that obtained with conventional electrodes (p < .0001). Finally, normalized amplitude values were equivalent across swallows (5 ml: p < .025; 10 ml: p < .0012), and sEMG burst duration was also equivalent (5 ml: p < .0001; 10 ml: p < .0001). Safety/preclinical factors: The experimental patch resulted in fewer mild adverse effects. Participant satisfaction was higher with the experimental patch (p = .0476, d =0.226). Conclusions: Our new wearable sEMG patch is equivalent with widely used conventional sEMG electrodes in terms of technical performance. In addition, our patch is safe, and healthy older adults are satisfied with it. With lessons learned from the current COVID-19 pandemic, efforts to develop optimal swallowing telerehabilitation devices are more urgent than ever. Upon further validation, this new technology has the potential to improve rehabilitation and telerehabilitation efforts for patients with dysphagia. Supplemental Material: https://doi.org/10.23641/asha. 12915509.

Original languageEnglish (US)
Pages (from-to)3293-3310
Number of pages18
JournalJournal of Speech, Language, and Hearing Research
Volume63
Issue number10
DOIs
StatePublished - Oct 2020

Funding

This study was partially supported by the Ralph W. and Grace M. Showalter Research Trust (PIs: Malandraki and Lee), the Purdue Institute for Integrative Neuroscience (PIs: Kantarcigil and Malandraki), and the National Institute of Biomedical Imaging and Bioengineering R21 Trailblazer (Grant 1R21EB026099-01A1, PIs: Lee and Malandraki). The authors wish to thank all participants. In addition, the authors would like to thank Katie Bolte, Paige Cornillie, Sam S. Mitchell, and Jennine L. Bryan for their help with data collection and management. The authors would also like to thank Satya Parida for his assistance in writing the MATLAB code for the electromyography analysis. A portion of this work was presented at the Dysphagia Research Society’s Annual Meeting in San Diego, California, in March 2019.

ASJC Scopus subject areas

  • Speech and Hearing
  • Language and Linguistics
  • Linguistics and Language

Fingerprint

Dive into the research topics of 'Validation of a novel wearable electromyography patch for monitoring submental muscle activity during swallowing: A randomized crossover trial'. Together they form a unique fingerprint.

Cite this