TY - JOUR
T1 - Variations in rotation of the aortic root and membranous septum with implications for transcatheter valve implantation
AU - Tretter, Justin T.
AU - Mori, Shumpei
AU - Saremi, Farhood
AU - Chikkabyrappa, Sathish
AU - Thomas, Kristen
AU - Bu, Fang
AU - Loomba, Rohit S.
AU - Alsaied, Tarek
AU - Spicer, Diane E.
AU - Anderson, Robert H.
N1 - Publisher Copyright:
© 2018 BMJ Publishing Group. All rights reserved.
PY - 2018/6
Y1 - 2018/6
N2 - Objective it is intuitive to suggest that knowledge of the variation in the anatomy of the aortic root may influence the outcomes of transcatheter implantation of the aortic valve (taVi). We have now assessed such variation. Methods We used 26 specimens of normal hearts and 78 ct data sets of adults with a mean age of 64±15 years to measure the dimensions of the membranous septum and to assess any influence played by rotation of the aortic root, inferring the relationship to the atrioventricular conduction axis. results the aortic root was positioned centrally in the majority of both cohorts, although with significant variability. For the cadaveric hearts, 14 roots were central (54%), 4 clockwise-rotated (15%) and 8 counterclockwise-rotated (31%). in the adult ct cohort, 44 were central (56%), 21 clockwise-rotated (27%) and 13 counterclockwise-rotated (17%). a mean angle of 15.5° was measured relative to the right fibrous trigone in the adult ct cohort, with a range of −32° to 44.7°. the dimensions of the membranous septum were independent of rotation. Fibrous continuity between the membranous septum and the right fibrous trigone increased with counterclockwise to clockwise rotation, implying variation in the relationship to the atrioventricular conduction axis. Conclusions the central fibrous body is wider, providing greater fibrous support, in the setting of clockwise rotation of the aortic root. individuals with this pattern may be more vulnerable to conduction damage following taVi. Knowledge of such variation may prove invaluable for risk stratification.
AB - Objective it is intuitive to suggest that knowledge of the variation in the anatomy of the aortic root may influence the outcomes of transcatheter implantation of the aortic valve (taVi). We have now assessed such variation. Methods We used 26 specimens of normal hearts and 78 ct data sets of adults with a mean age of 64±15 years to measure the dimensions of the membranous septum and to assess any influence played by rotation of the aortic root, inferring the relationship to the atrioventricular conduction axis. results the aortic root was positioned centrally in the majority of both cohorts, although with significant variability. For the cadaveric hearts, 14 roots were central (54%), 4 clockwise-rotated (15%) and 8 counterclockwise-rotated (31%). in the adult ct cohort, 44 were central (56%), 21 clockwise-rotated (27%) and 13 counterclockwise-rotated (17%). a mean angle of 15.5° was measured relative to the right fibrous trigone in the adult ct cohort, with a range of −32° to 44.7°. the dimensions of the membranous septum were independent of rotation. Fibrous continuity between the membranous septum and the right fibrous trigone increased with counterclockwise to clockwise rotation, implying variation in the relationship to the atrioventricular conduction axis. Conclusions the central fibrous body is wider, providing greater fibrous support, in the setting of clockwise rotation of the aortic root. individuals with this pattern may be more vulnerable to conduction damage following taVi. Knowledge of such variation may prove invaluable for risk stratification.
UR - http://www.scopus.com/inward/record.url?scp=85058023367&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85058023367&partnerID=8YFLogxK
U2 - 10.1136/heartjnl-2017-312390
DO - 10.1136/heartjnl-2017-312390
M3 - Article
C2 - 29146623
AN - SCOPUS:85058023367
SN - 1355-6037
VL - 104
SP - 999
EP - 1005
JO - Heart
JF - Heart
IS - 12
ER -