T1 - Ventricular tachyarrhythmias in patients receiving an implantable cardioverter-defibrillator for primary versus secondary prophylaxis indications
AU - Manuchehry, Amin
AU - Agusala, Kartik
AU - Montevecchi, Mauro
AU - Kadish, Alan
AU - Passman, Rod
N1 - Copyright:
Copyright 2011 Elsevier B.V., All rights reserved.
PY - 2011/5
Y1 - 2011/5
N2 - Introduction: Data on the mechanisms of sudden cardiac death are limited and may be biased by delays in rhythm recording and selection bias in survivors. As a result, the relative contributions of monomorphic ventricular tachycardia (VT) (cycle length [CL] > 260 ms), monomorphic fast VT (FVT) (CL ≤ 260 ms), and polymorphic VT (PMVT)/ventricular fibrillation (VF) have not been well characterized nor compared in patients with and without prior arrhythmic events. Methods: A retrospective cohort study of implantable cardioverter-defibrillator (ICD) recipients with primary or secondary implant indications was used to evaluate intracardiac electrograms (EGMs) for the first spontaneous VT/VF resulting in appropriate ICD therapy. EGMs were categorized into VT, FVT, and PMVT/VF based on CL and morphologic criteria. Results: Of 616 implants, 145 patients (58 [40%] primary indications) received appropriate ICD therapy for VT/VF over mean follow-up of 3.8 ± 3.2 years. Primary implants had more diabetes (28% vs 12%; P = 0.02) and less antiarrhythmic use (15% vs 33%; P = 0.02). In those patients with spontaneous arrhythmia, PMVT/VF occurred in 20.7% of primary versus 21.8% of secondary implants, FVT in 19.0% versus 21.8%, and VT in 60.3% versus 56.4%, respectively (P = 0.88). Spontaneous VT CL was similar regardless of implant indication (284 ± 56 [primary] vs 286 ± 67 ms [secondary]; P = 0.92). Conclusions: Monomorphic VT is the most common cause of appropriate ICD therapy regardless of implant indication. These results provide insight into the mechanisms of sudden cardiac death and have implications for the use of interventions designed to limit ICD shocks.
AB - Introduction: Data on the mechanisms of sudden cardiac death are limited and may be biased by delays in rhythm recording and selection bias in survivors. As a result, the relative contributions of monomorphic ventricular tachycardia (VT) (cycle length [CL] > 260 ms), monomorphic fast VT (FVT) (CL ≤ 260 ms), and polymorphic VT (PMVT)/ventricular fibrillation (VF) have not been well characterized nor compared in patients with and without prior arrhythmic events. Methods: A retrospective cohort study of implantable cardioverter-defibrillator (ICD) recipients with primary or secondary implant indications was used to evaluate intracardiac electrograms (EGMs) for the first spontaneous VT/VF resulting in appropriate ICD therapy. EGMs were categorized into VT, FVT, and PMVT/VF based on CL and morphologic criteria. Results: Of 616 implants, 145 patients (58 [40%] primary indications) received appropriate ICD therapy for VT/VF over mean follow-up of 3.8 ± 3.2 years. Primary implants had more diabetes (28% vs 12%; P = 0.02) and less antiarrhythmic use (15% vs 33%; P = 0.02). In those patients with spontaneous arrhythmia, PMVT/VF occurred in 20.7% of primary versus 21.8% of secondary implants, FVT in 19.0% versus 21.8%, and VT in 60.3% versus 56.4%, respectively (P = 0.88). Spontaneous VT CL was similar regardless of implant indication (284 ± 56 [primary] vs 286 ± 67 ms [secondary]; P = 0.92). Conclusions: Monomorphic VT is the most common cause of appropriate ICD therapy regardless of implant indication. These results provide insight into the mechanisms of sudden cardiac death and have implications for the use of interventions designed to limit ICD shocks.
KW - Defibrillation-ICD
KW - Electrophysiology-clinical
KW - VT
UR - http://www.scopus.com/inward/record.url?scp=79957683003&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79957683003&partnerID=8YFLogxK
U2 - 10.1111/j.1540-8159.2010.03004.x
DO - 10.1111/j.1540-8159.2010.03004.x
M3 - Article
C2 - 21208242
AN - SCOPUS:79957683003
SN - 0147-8389
VL - 34
SP - 571
EP - 576
JO - PACE - Pacing and Clinical Electrophysiology
JF - PACE - Pacing and Clinical Electrophysiology
IS - 5
ER -