Virtual electrode-induced phase singularity: A basic mechanism of defibrillation failure

Igor R. Efimov*, Yuanna Cheng, David R. Van Wagoner, Todor Mazgalev, Patrick J. Tchou

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

238 Scopus citations

Abstract

Delivery of a strong electric shock to the heart remains the only effective therapy against ventricular fibrillation. Despite significant improvements in implantable cardioverter defibrillator (ICD) therapy, the fundamental mechanisms of defibrillation remain poorly understood. We have recently demonstrated that a monophasic defibrillation shock produces a highly nonuniform epicardial polarization pattern, referred to as a virtual electrode pattern (VEP). The VEP consists of large adjacent areas of strong positive and negative polarization. We sought to determine whether the VEP may be responsible for defibrillation failure by creating dispersion of postshock repolarization and reentry. Truncated exponential biphasic and monophasic shocks were delivered from a bipolar ICD lead in Langendorff- perfused rabbit hearts. Epicardial electrical activity was mapped during and after defibrillation shocks and shocks applied at the plateau phase of a normal action potential produced by ventricular pacing. A high-resolution fluorescence mapping system with 256 recording sites and a voltage-sensitive dye were used. Biphasic shocks with a weak second phase (<20% leading-edge voltage of the second phase with respect to the leading-edge voltage of the first phase) produced VEPs similar to monophasic shocks. Biphasic shocks with a strong second phase (>70%) produced VEPs of reversed polarity. Both of these waveforms resulted in extra beats and arrhythmias. However, biphasic waveforms with intermediate second-phase voltages (20% to 70% of first-phase voltage) produced no VEP, because of an asymmetric reversal of the first- phase polarization. Therefore, there was no substrate for postshock dispersion of repolarization. Shocks producing strong VEPs resulted in postshock reentrant arrhythmias via a mechanism of phase singularity. Points of phase singularity were created by the shock in the intersection of areas of positive, negative, and no polarization, which were set by the shock to excited, excitable, and refractory states, respectively. Shock-induced VEPs may reinduce arrhythmias via a phase-singularity mechanism. Strong shocks may overcome the preshock electrical activity and create phase singularities, regardless of the preshock phase distribution. Optimal defibrillation waveforms did not produce VEPs because of an asymmetric effect of phase reversal on membrane polarization.

Original languageEnglish (US)
Pages (from-to)918-925
Number of pages8
JournalCirculation research
Volume82
Issue number8
DOIs
StatePublished - May 4 1998

Keywords

  • Defibrillation waveform
  • Implantable cardioverter defibrillator
  • Mechanism of defibrillation
  • Optical imaging
  • Voltage-sensitive dye

ASJC Scopus subject areas

  • Physiology
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Virtual electrode-induced phase singularity: A basic mechanism of defibrillation failure'. Together they form a unique fingerprint.

Cite this