Which sevoflurane wash-in rates towards 1.0 MAC ensure adequate anesthetic depth after a standardized intravenous induction before surgical incision?

M. Van Thielen*, R. Carette, S. De Hert, A. M. De Wolf, J. F.A. Hendrickx

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

Background: After intravenous (IV) induction of anesthesia, inhaled agent wash-in has to be titrated in such a manner that the combined effects of this agent and remaining opioid and propofol continue to ensure loss of consciousness (LOC) prior to incision. We assessed the effect of different sevoflurane wash-in rates on anesthetic depth. Methods: Anesthesia was induced with sufentanil (0.2 μg/kg), followed 4 min later by propofol (1-2 mg/ kg, depending on age), and rocuronium (0.6 mg/kg) in 33 ASA PS I-III patients. After tracheal intubation, sevoflurane wash-in towards 1 age-adjusted minimal alveolar concentration (MAC) was controlled to occur exponentially with a time constant of 2.5, 5.0, or 11.1 min, depending on the anticipated time of incision: FAST, MEDIUM, or SLOW, respectively. The effect-site MAC (MACe), sufentanil effect site concentration (CeSuf), Noxious Stimulation Response Index, Bispectral Index (BIS), and Brice questionnaire defined 3 probabilities of LOC (PLOC): extremely high, i.e. MACe > 0.63 and CeSuf > 0.17 ng/mL or NSRI < 50 and BIS < 65; high, i.e. 50 < NSRI < 70 and BIS < 65 or NSRI < 50 and BIS > 65; and insufficient, i.e. NSRI > 50 and BIS > 65 or recall elicited by the Brice questionnaire. Results: The end-expired sevoflurane concentration rose towards 1 MAC with a time constant (95% con-fidence interval) of 2.6 (2.6; 2.7), 5.7 (5.3; 6.2), and 10.9 (9.6; 12.6) min in groups FAST, MEDIUM, and SLOW, respectively. 0.63 MACe was reached at 9.8 [9.8; 9.8], 12.3 [12.3; 12.6], and 18.5 [18.3; 18.7] min (median and interquartile range), for groups FAST, MEDIUM, and SLOW, respectively, with CeSuf > 0.17 ng/mL at the moment 0.63 MACe was reached in all but 2 patients in group SLOW. Before reaching 0.63 MACe, PLOC was high to extremely high in group FAST and MEDIUM patients, but insufficient in group SLOW, even though the modified Brice questionnaire did not elicit any recall. Conclusion: An exponential end-expired sevoflu-rane wash-in rate towards 1.0 MAC with a time constant ≤ 5.7 min but not ≥ 10.9 min ensures hypnosis after IV induction with propofol (1-2 mg/kg), preceded 4 min earlier by sufentanil (0.2 μg/kg). Integrating these patterns into automated low-flow target controlled algorithms may help optimize anesthetic agent delivery.

Original languageEnglish (US)
Pages (from-to)159-165
Number of pages7
JournalActa anaesthesiologica Belgica
Volume72
StatePublished - Dec 2021

Funding

The study has not been funded. Jan Hendrickx has received lecture support, travel reimbursements, equipment loans, consulting fees and/or meeting organizational support from a number of companies involved with inhaled agent delivery (alphabetically): AbbVie, Acertys, Air Liquide, Allied healthcare, Armstrong Medical, Baxter, Draeger, GE, Hospithera, Heinen und Lowensein, InnoMediq, Intersurgical, Maquet, MDMS, MEDEC, Micropore, Mindray, Molecular, NWS, Philips, Quantum Medical.

Keywords

  • anesthetic depth
  • inhaled agents
  • pharmacokinetics
  • sevoflurane
  • synergy

ASJC Scopus subject areas

  • Anesthesiology and Pain Medicine

Fingerprint

Dive into the research topics of 'Which sevoflurane wash-in rates towards 1.0 MAC ensure adequate anesthetic depth after a standardized intravenous induction before surgical incision?'. Together they form a unique fingerprint.

Cite this